VEGA VEGAWELL 51 4 … 20 mA_HART User Manual
Page 33
Advertising
-
M
ax. length
1000
m (3280 ft)
-
M
in. bending radius
25
mm (with 25 °C/77 °F)
-
D
iameter approx.
8
mm (0.315 in)
-
colour (non-Ex/Ex) - PE
black/blue
-
colour (non-Ex/Ex) - PUR, FEP
blue/blue
Voltage supply
S
upply voltage
-
N
on-Ex instrument
9.6 … 36 V DC
-
EE
x-ia instrument
9.6 … 30 V DC
P
ermissible residual ripple
-
<
100 H
z
U
ss
<
1 V
-
100 H
z … 10 kHz
U
ss
<
10
mV
L
oad
see diagram
1200
880
600
380
12
18
16
9,6
14
20
22
24
26
28
29 30
32
34
36
Ω
V
1
4
2
3
Fig. 10: Voltage diagram
1
HART load
2
Voltage limit Ex instrument
3
Voltage limit non-Ex instrument
3
Supply voltage
Integrated overvoltage protection
N
ominal leakage current (8/20 µs)
5
kA
M
in. response time
<
25
ns
Electrical protective measures
P
rotection
-
T
ransmitter
IP
68 (25
bar)
S
upplement
VEGAWELL
51 • 4 … 20
mA/HART
33
32468
-
EN
-080604