background image

Fig. 29: Max. lateral load alongside fork side (narrow fork side)

Output variable

Output

Relay output (DPDT), 2 floating spdts
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.

Turn-on voltage

-

Min.

10 mV

-

Max.

253 V AC, 253 V DC
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.

Switching current

-

Min.

10 µA

-

Max.

3 A AC, 1 A DC

Breaking capacity

-

Min.

50 mW

-

Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

min./max.

Switching delay

-

When immersed

0.5 s

-

When laid bare

1 s

Ambient conditions

Ambient temperature on the housing

-40 … +80 °C (-40 … +176 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Measured variable

Limit level of solids