VEGA VEGAFLEX 66 (-200…+400°C) 4 … 20 mA_HART two-wire User Manual
Page 56
L
0
-3 mm (-0.118
")
3 mm (0.118
")
-10 mm (-0.394
")
5 mm (0.197
")
-5 mm (-0.197
")
0,15 m (5.906
"
)
0,06 m (2.362
"
)
0,05 m
(1.968
")
0,1 m
(3.937
")
1
1
Fig. 31: Deviation VEGAFLEX 66 in coax version in water
1
Dead zone - no measurement possible in this area
L
Probe length
L
0
-3 mm (-0.118
")
3 mm (0.118
")
-10 mm (-0.394
")
10 mm (0.394
")
0,1 m (3.937
"
)
0,15 m
(1.968
")
0,1 m
(3.937
")
0,25 m (9.842
"
)
1
1
Fig. 32: Deviation VEGAFLEX 66 in coax version in oil
1
Dead zone - no measurement possible in this area
L
Probe length
Influence of the ambient temperature to the sensor electronics
T
emperature drift
0.03 %/10 K
relating to the max. measuring range
or max. 0.3 %
T
emperature drift - Digital output
3
mm/10 K relating to the max. measuring range or
max. 10 mm
Ambient conditions
A
mbient, storage and transport temperature
-
40 … +80 °C (-40 … +176 °F)
56
VEGAFLEX
66 • 4 … 20
mA/HART two-wire
10 S
upplement
34173
-EN
-100427