VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Profibus PA User Manual

Page 42

Advertising
background image

42

6 Set up with the indicating and adjustment module

VEGAPULS 62 • Profibus PA

36505-EN-121011

Enter the requested parameters via the appropriate keys, save your

settings with [OK] and jump to the next menu item with the [ESC] and

the [->] key.

With this selection, the operating range of the sensor is adapted to

the vessel height and the reliability with different frame conditions is

increased considerably.
Independent from this, the min. adjustment must be carried out.

Enter the requested parameters via the appropriate keys, save your

settings with [OK] and jump to the next menu item with the [ESC] and

the [->] key.

Since a radar sensor is a distance measuring instrument, the distance

from the sensor to the product surface is measured. For indication of

the real level, an allocation of the measured distance to the percent-

age height must be carried out.
To perform the adjustment, enter the distance with full and empty ves-

sel, see the following example:

100%

0%

0,5 m (19.68

")

5 m

(196.9

")

2

1

Fig. 37: Parameter adjustment example min./max. adjustment
1 Min. level = max. meas. distance

2 Max. level = min. meas. distance

If these values are not known, an adjustment with the distances of for

example 10 % and 90 % is possible. Starting point for these distance

Setup/Vessel height,

measuring range

Setup/Adjustment

Advertising