5 wiring plan, double chamber housing ex d, Connection compartment – VEGA VEGAPULS SR 68 Profibus PA User Manual
Page 34
34
5 Connecting to power supply
VEGAPULS SR 68 • Profibus PA
38296-EN-130624
+
Bus
2
3
1
2
( )
(-)
1
Fig. 31: Connection compartment, double chamber housing
1 Voltage supply, signal output
2 For display and adjustment module or interface adapter
3 Ground terminal for connection of the cable screen
1
Bus
USB
Status
Test
SIM-Card
1
2
+
( )
(-)
Fig. 32: Connection compartment radio module PLICSMOBILE
1 Voltage supply
You can find detailed information on connection in the supplementary
instructions "PLICSMOBILE GSM/GPRS radio module".
5.5 Wiring plan, double chamber housing Ex d
5 6 7 8
1
2
+
( )
(-)
3
1
2
4...20mA
Fig. 33: Electronics compartment, double chamber housing
1 Internal connection to the connection compartment
2 For display and adjustment module or interface adapter
3 Internal connection to the plug connector for external display and adjust-
ment unit (optional)
Connection compartment
Connection compartment
- Radio module PLICS-
MOBILE
Electronics compartment