7 setup with pactware, 1 connect the pc – VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) standpipe ver. 4 … 20 mA_HART - four-wire User Manual
Page 30
30
7 Setup with PACTware
VEGAPULS 62 standpipe version • 4 … 20 mA/HART - four-wire
36508-EN-121011
7 Setup with PACTware
7.1 Connect the PC
3
1
2
Fig. 11: Connection of the PC directly to the sensor via the interface adapter
1 USB cable to the PC
2 Interface adapter VEGACONNECT 4
3 Sensor
Information:
The interface adapter VEGACONNECT 3 is not suitable for connec-
tion to the sensor.
1
5
2
4
3
OP
EN
TWIST
USB
LOCK
Fig. 12: Connecting the PC via HART to the signal cable
1 VEGAPULS 62
2 HART resistance 250 Ω (optional depending on processing)
3 Connection cable with 2 mm pins and terminals
4 Processing system/PLC/Voltage supply
Necessary components:
•
VEGAPULS 62
•
PC with PACTware and suitable VEGA DTM
•
VEGACONNECT 4
•
HART resistance approx. 250 Ω
Via the interface adapter
directly on the sensor
Connection via HART