3 product description – VEGA VEGASOURCE 35 User Manual

Page 9

Advertising
background image

9

3 Product description

VEGASOURCE 35 •

38132-EN-130415

3 Product description

3.1 Configuration

The nameplate contains the most important data for identification and

use of the instrument:

•

Order code

•

Serial number

•

Source container

•

Contained source (gamma emitter)

•

Radionuclide

•

Activity

•

Local dose rate

•

Article number - documentation

•

Note: "Highly radioactive source" (if necessary)

The serial number allows you to access the delivery data of the instru-

ment via www.vega.com, "VEGA Tools" and "serial number search".
Note:

The local dose rate stated on the type label at a defined distance is

safety-oriented and includes production-related fluctuations of the

emitters as well as tolerances of the measuring instruments. There

can thus be deviations in the local dose rate calculated with the speci-

fied attenuation factors. See also "Principle of operation/Source".
Note:

With sources exceeding a certain level of activity, the warning "Highly

radioactive source" must be stated on the type label.
This is the case for Co-60 with an activity ≥ 4 GBq (108 mCi) or for

Cs-137 with an activity ≥ 20 GBq (540 mCi).

There are several versions available with different options for opening

or locking the beam exit. Apart from the manual versions, there are

also versions with pneumatic switchover.

Type plate

Versions

Advertising