5 connection of the pneumatic switchich facility – VEGA VEGASOURCE 31 User Manual

Page 28

Advertising
background image

28

5 Connection of the pneumatic switchich facility

VEGASOURCE 31 •

38131-EN-130415

5 Connection of the pneumatic switchich

facility

5.1 Connection of the proximity switches

These instructions apply to source containers VEGASOURCE 31 ver-

sion K, L, M, N with pneumatic switching facility.

Always keep in mind the following safety instructions:

•

Connect only in the complete absence of line voltage

•

If overvoltage surges are expected, overvoltage arresters should

be installed

Connect the proximity switches according to the following diagrams.

Take note of the general installation regulations. As a rule, connect

VEGASOURCE 31 to vessel ground (PA), or in case of plastic ves-

sels, to the next ground potential. On the upper side of the instrument

protective cover there is a ground terminal between the cable entries.

This connection serves to drain off electrostatic charges. In Ex ap-

plications, the installation regulations for hazardous areas must be

given priority.
The data for power supply are specified in chapter "Technical data".

The instrument is connected with standard two-wire cable without

screen.
Use cable with round cross-section. A cable outer diameter of

5 … 10 mm (0.2 … 0.39 in) ensures the seal effect of the cable gland.

If you are using cable with a different diameter or cross-section,

exchange the seal or use a suitable cable gland.

Suitable proximity switch: Pepperl+Fuchs 181094-NCB2-12GM35-

NO-10M

1

2

1 2 3 4

br bl br bl

+ - + -

Fig. 21: Connection of the proximity switches
1 Proximity switch for switch position EIN - ON (terminals 1 and 2)

2 Proximity switch for switch position AUS - OFF (terminals 3 and 4)

Safety instructions

Potential equalisation

Connection cable

Electrical connection