VEGA VEGAFLEX 86 Modbus and Levelmaster protocol Coax probe User Manual

Page 10

Advertising
background image

10

3 Product description

VEGAFLEX 86 • Modbus and Levelmaster protocol

42288-EN-130314

2

1

Fig. 4: Position of Modbus and sensor electronics
1 Modbus electronics

2 Sensor electronics

This operating instructions manual applies to the following instrument

versions:

•

Hardware from 1.0.0

•

Software from 1.0.0

•

Only for instrument versions without SIL qualification

The respective electronics version can be determined via the product

code on the type label as well as on the electronics.

•

Standard electronics: Type FX80HK.-

The scope of delivery encompasses:

•

Sensor

•

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Operating instructions manual "Display and adjustment mod-

ule" (optional)

– Supplementary instructions "GSM/GPRS radio module"

(optional)

– Supplementary instructions manual "Heating for display and

adjustment module" (optional)

– Supplementary instructions manual "Plug connector for con-

tinuously measuring sensors" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAFLEX 86 is a level sensor with coax probe for continuous

level or interface measurement, suitable for applications in liquids

with high temperatures up to 450 °C (842 °F).

High frequency microwave pulses are guided along a steel cable or

a rod. Upon reaching the product surface, the microwave pulses are

reflected. The running time is evaluated by the instrument and output-

ted as level.

Scope of this operating

instructions manual

Versions

Scope of delivery

Application area

Functional principle -

level measurement

Advertising