1
2
Fig. 11: Installation with vessel vibrations
1
Anti vibration blocks or rubber buffers
2
Window of non-conductive material, for example, glass, plastic, etc.
Angle
For an optimum switching signal, the two sensors must be adapted to
each other. The accuracy must be in a range of ±5°.
Offset
The two sensors can have an offset of up to < 5 % of the sensor
distance (d) to each other. Example: with a sensor distance of
1000 mm, the two sensors must have an offset of max. 50 mm to each
other.
General rule: the bigger the antenna and the better it focusses, the
more precise the orientation has to be.
5
°
+ -
d
<
d
2
0
Fig. 12: Orientation of the sensors - Angle and offset