Vessel: small laterally mounted or large top mounted stirrer

•

Process/measurement conditions:

– Relatively smooth product surface

– Max. requirement to the measurement accuracy

– Condensation

– Slight foam generation

– Overfilling possible

Storage tank on ships (Cargo Tank):

•

Product speed: slow filling and emptying

•

Vessel:

– Installations in the bottom section (bracers, heating spirals)

– High sockets 200 … 500 mm, also with large diameters

•

Process/measurement conditions:

– Condensation, buildup by movement

– Max. requirement on measurement accuracy from 95 %

Stirrer vessel (reactor):

•

Setup: all vessel sizes possible

•

Product speed:

– Fast to slow filling possible

– Vessel is very often filled and emptied

•

Vessel:

– Socket available

– Large agitator blades of metal

– Vortex breakers, heating spirals

•

Process/measurement conditions:

– Condensation, buildup by movement

– Strong spout generation

– Very agitated surface, foam generation

Dosing vessel:

•

Setup: all vessel sizes possible

•

Product speed:

– Fast filling and emptying

– Vessel is very often filled and emptied

•

Vessel: narrow installation situation

•

Process/measurement conditions:

– Condensation, buildup on the antenna

– Foam generation

Standpipe:

•

Product speed: very fast filling and emptying

•

Vessel:

– Vent hole

– Joins like flanges, weld joints

– Shifting of the running time in the tube

•

Process/measurement conditions:

– Condensation

– Buildup

Bypass:

•

Product speed: