9 Supplement
VEGASWING 51 • - contactless electronic switch
41045-EN-130322
Output variable
Output
Contactless electronic switch
Modes min / max (changeover by electrical connection)
Ʋ Max.
Max. detection or overflow/overfill protection
Ʋ Min.
Min. detection or dry run protection
Voltage supply
Operating voltage
20 … 253 V AC/DC
Power consumption
max. 0.5 W
Electromechanical data
Valve plug ISO 4400
Ʋ Wire cross-section
1.5 mm² (0.06 in²)
Ʋ Outer cable diameter
4.5 … 7 mm (0.18 … 0.28 in)
Valve plug ISO 4400 with IDC method of termination
Ʋ Wire cross-section
for wire cross-section of 0.5 … 1 mm² (0.02 … 0.04 in²)
Ʋ Single-wire diameter
> 0.1 mm (0.004 in)
Ʋ Wire diameter
1.6 … 2 mm² (0.06 … 0.08 in²)
Ʋ Outer cable diameter
5.5 … 8 mm (0.22 … 0.31 in)
Ʋ Connection frequency
10 x (on the same cross-section)
Electrical protective measures
Protection rating
Ʋ Valve plug ISO 4400
IP 65
Ʋ Valve plug ISO 4400 with IDC method
of termination
IP 67
Overvoltage category
III
Protection class
I
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"