7 supplement, 1 technical data – VEGA VEGABAR 86 Save sensor - Quick setup guide User Manual
Page 18

18
7 Supplement
VEGABAR 86 • Slave sensor for electronic differential pressure
46334-EN-131125
7 Supplement
7.1 Technical data
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ Cable diameter (options)
5 … 9 mm (0.20 … 0.35 in)
6 … 12 mm (0.24 … 0.47 in)
10 … 14 mm (0.39 … 0.55 in)
Ʋ Cable entry
½ NPT
Ʋ Blind plug
M20 x 1.5; ½ NPT
Ʋ Closing cap
M20 x 1.5; ½ NPT
Plug options
Ʋ Signal circuit
Plug M12 x 1, according to ISO 4400, Harting HAN,
7/8" FF
Ʋ Indication circuit
M12 x 1 plug
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Voltage supply, interface to the master sensor
Voltage supply
Through the master sensor
Data transmission
digital (I²C-Bus)
Configuration, connection cable
4-wire, screened
Cable length max.
25 m