eBridge1PCR/PCT

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
eBridge1PCT and eBridge1PCR are not intended to be connected to outside plant leads and should be installed indoors
within the protected premises. eBridge1PCT and eBridge1PCR are intended for indoor use only.
1.

eBridge1PCR installation:

a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole
(Fig. 2a, pg. 3). Unit should be mounted in proximity to ethernet switch/network, NVR or video server.
b. Connect 24VAC Class 2 plug-in transformer or 24VDC (polarity not observed) Class 2 power supply to wire insert
connector [Power Input] (Fig. 1, pg. 2). Use 22AWG-16AWG wire for this connection.
c. Connect structured cable from ethernet switch/NVR (network video server) to RJ45 jack marked [10/100BaseT]
(Fig. 2, pg. 3).
d. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
2.

eBridge1PCT installation:

a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 2a, pg. 3). Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).

Note: The eBridge1PCRT is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is
important to note that some high resolution and high frame rate cameras may demand faster headend processing ability,
such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the
image may show pixilation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolu-
tion may be reduced to accommodate system equipment.

Technical Specifications:

Parameter

Description

Connections

BNC for Coax link. RJ45 for ethernet link.

Input power requirements 24VDC/1,000mA, 24VAC/900mA
Indicators

Blue: Coax Link.
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Green: Power.

Environmental
Conditions

Operating Ambient Temperature:
UL60950-1
eBridge1PCR: --- 4ºF to 113ºF (--- 20ºC to +45ºC).
eBridge1PCT: --- 4ºF to 140ºF (--- 20ºC to +60ºC).
Relative humidity: 85%, +/ --- 5%
Storage Temperature: --- 4º to 158ºF (--- 20º to 70ºC) Storage
Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).

Regulatory Compliance

UL/CUL Listed for Information Technology Equipment (UL 60950-1).
CE approved. C-Tick compliant.

Weights (approx.)

Product: 5.1 oz. (0.144 kg.), Shipping: 7.76 oz. (0.22 kg.)

Fig. 1

eBridge1PCR

eBridge1PCT

Green LED

indicates

Power

Structured

Cable from

Ethernet Switch/NVR

Structured

Cable from

IP Camera/Device

Blue LED

indicates

Coax Connection

Blue LED

indicates

Coax Connection

Green LED

indicates

Power

Yellow LED

indicates

PoE

Coax

Cable from

eBridge1PCT

24VAC/VDC

Input

Coax

Cable from

eBridge1PCR