Altronix NetWay8 Installation Instructions User Manual
Page 3

NetWay8/NetWay16
- 3 -
AC POWER
NetWay8 & NetWay16 - Rear Panel
NetWay8 - Front Panel
NetWay16 - Front Panel
1a
1b
1c
1d
1e
Port Status and LED Flash Codes:
Port Status
Flash Codes
Description
All Ports Off
Sequential LED Port Scan
No devices connected
Port Off
OFF
LED OFF
Port On
ON
LED ON
Class 4 detection Port
Blinks 2 times
Non-compliant Port
2Hz
Port Overload Fault
5Hz
4 Port Overload Grouped
5Hz
4 LEDs
8 Port Overload Grouped
5Hz
LED’s 1-8 Power Supply Overload for ports 1-8.
LED’s 9-16 Power Supply Overload for ports 9-16.
Fig. 1
1a OUT 1-8 (NetWay8), OUT 1-16 (NetWay16): Structured cable to PoE compliant cameras/edge devices.
1b IN 1-8 (NetWay8), IN 1-16 (NetWay16): Structured cable to ethernet switch or video server.
1c LED(s) 1-8 (NetWay8), 1-16 (NetWay16): Port status LEDs.
1d Illuminated master power disconnect circuit breaker (switch):
• OFF position Circuit breaker tripped Switch not illuminated.
• RESET (ON) position Switch illuminated.
1e IEC 320 Connector: 115VAC 60Hz (grounded line cord included).