These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via thirty-two (32) fuse or
PTC protected outputs for powering CCTV Cameras, heaters and other video accessories.

Thirty-two (32) Output Rack Mount Configuration Reference Chart:

Altronix

Model Number

Output Voltage

(VAC)

Total

Output

Current (Power)

Number of Outputs

PTC Protected Outputs (Class 2 power- limited for Dry locations). (Class 3 for Wet locations).

Fuse Protected Class 1 Outputs

Individual Output Current (max per output not to exceed total output current)

Fuse Ratings

115VAC 50/60Hz Input Current

Agency Listings

R2432300UL

24VAC

12.5 amp

32

Yes

3.5 amp

3.5 amp 3 amp

28VAC

10 amp

R2432300ULCB

24VAC

12.5 amp

32

Yes

2.5 amp

3 amp

28VAC

10 amp

R2432600UL*

24VAC

25 amp

32

Yes

3.5 amp

3.5 amp 6 amp

28VAC

20 amp

R2432600ULCB*

24VAC

25 amp

32

Yes

2.5 amp

6 amp

28VAC

20 amp

*24VAC models: Outputs 1-16 provide 12.5 amp (300VA) max. Outputs 17-32 provide 12.5 amp (300VA) max.
*28VAC models: Outputs 1-16 provide 10 amp (280VA) max. Outputs 17-32 provide 10 amp (280VA) max.

Specifications:

Installation Instructions:

1. The unit is factory set for 24VAC operation.

For 28VAC operation, adjust unit prior to mounting and applying power as follows:

a. Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing & Dimensions, pg. 4).

b. Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and

the yellow wire [24V] is connected to the terminal marked [S] (Fig. 1d, pg. 3).

c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six (6) screws.

2. Mount unit in the desired rack location (Space unit at least 3” from any video monitors). Do not obstruct side air vents.
3. Set power disconnect circuit breaker to the OFF position (Fig. 1c, pg. 3).
4. Plug power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1b, pg. 3), ground should be connected

as indicated in (Fig. 1e, pg. 3).

5. Set power disconnect circuit breaker to the RESET (ON) position and measure output voltage before

connecting devices (Fig. 1c, pg. 3). This helps avoiding potential damage. All terminals with common

suffix (P) “1P, 2P...” are the same polarity.

6. Set power disconnect circuit breaker to the OFF position (Fig. 1c, pg. 3).
7. Connect devices to the removable terminal blocks marked [1P & 1N through 8P & 8N] (Fig. 1a, pg. 3).

When wiring is completed on the terminal blocks, they can be locked down by tightening screw flanges.

Agency Listings:

• UL Listed for Commercial CCTV Equipment (UL2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
CE - European Conformity

Input:

• 115VAC, 50/60Hz.

Output:

• Thirty-two (32) fuse or PTC protected outputs.
• 24VAC or 28VAC supply current.
• Outputs are rated @ 3.5 amp (fused) or 2.5 (PTC).
• Surge suppression.

Features:

• Thirty-two (32) individual power LED indicators.
• Illuminated master power disconnect circuit breaker
with manual reset.
• 3-wire grounded line cord.
• Removable terminal blocks with locking screw flange.
• Spare fuses provided.

Mechanical:

• 2U rack mount chassis for use in a standard
EIA 19” rack.
• Enclosure Dimensions (H x W x D approx.):
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)