Altronix ALTV248220 Series Installation Instructions User Manual

Page 2

Advertising
background image

- 2 -

ALTV248220series

Overview:

These Altronix CCTV Power Supplies provide provide 24VAC/28VAC distributed via eight (8) fuse or PTC protected
outputs for powering CCTV Cameras, heaters and other video accessories.

Eight (8) Output ALTV248220 Reference Chart:

Specifications:

Altronix

Model Number

• Surge suppression.
• AC power LED indicator.
• Illuminated power disconnect circuit breaker with
manual reset.
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).

Enclosure Dimensions:

ALTV248220, ALTV248CB220, ALTV248175220
and ALTV248175CB220: 216mm x 191mm x 89mm
ALTV248300M220 and ALTV248300CBM220:

216mm x 191mm x 95mm
ALTV248300220 and ALTV248300CB220:
311mm x 197mm x 114mm
ALTV248600220 and ALTV248600CB220:
343mm x 330mm x 83mm

ALTV248220

24VAC

4 amp

8

-------

P

3.5 amp

5 amp/250V

0.5 amp

28VAC

3.5 amp

ALTV248CB220

24VAC

4 amp

8

P

-------

2.5 amp

5 amp/250V

0.5 amp

28VAC

3.5 amp

ALTV248175220

24VAC 7.25 amp

8

-------

P

3.5 amp

10 amp/250V

0.7 amp

28VAC 6.25 amp

ALTV248175CB220

24VAC 7.25 amp

8

P

-------

2.5 amp

10 amp/250V

0.7 amp

28VAC 6.25 amp

ALTV248300220

24VAC

14 amp

8

-------

P

3.5 amp

15 amp/32V

1.35 amp

28VAC 12.5 amp

ALTV248300CB220

24VAC

14 amp

8

P

-------

2.5 amp

15 amp/32V

1.35 amp

28VAC 12.5 amp

ALTV248300M220

24VAC 12.5 amp

8

-------

P

3.5 amp

15 amp/32V

1.35 amp

28VAC

10 amp

ALTV248300CBM220

24VAC 12.5 amp

8

P

-------

2.5 amp

15 amp/32V

1.35 amp

28VAC

10 amp

ALTV248600220

24VAC

28 amp

8

-------

P

3.5 amp

(2) 15 amp/32V

2.7 amp

28VAC

25 amp

ALTV248600CB220

24VAC

28 amp

8

P

-------

2.5 amp

(2) 15 amp/32V

2.7 amp

28VAC

25 amp

Output

Voltage

Total

Output

Current

(Power)

Number

of

Outputs

PTC

Protected

Outputs Fuse

Protected

Outputs Output

Current

(max.

per

output)

Main

Fuse

Ratings

on

Board

220VAC

50/60Hz

Input

Current

Installation Instructions:

1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 6-8).
Secure enclosure to earth ground.

Advertising