C&H Technology PM25CLA120 User Manual

Page 4

Advertising
background image

3

PM25CLA120
Intellimod™ L-Series
Three Phase IGBT Inverter
25 Amperes/1200 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics, T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

IGBT Inverter Sector

Collector-Emitter Cutoff Current

I

CES

V

CE

= V

CES

, V

D

= 15V, T

j

= 25°C

1.0

mA

V

CE

= V

CES

, V

D

= 15V, T

j

= 125°C

10

mA

Diode Forward Voltage

V

EC

-I

C

= 25A, V

CIN

= 15V, V

D

= 15V

2.5

3.5

Volts

Collector-Emitter Saturation Voltage

V

CE(sat)

V

D

= 15V, V

CIN

= 0V, I

C

= 25A,

1.8

2.3

Volts

T

j

= 25°C

V

D

= 15V, V

CIN

= 0V, I

C

= 25A,

1.9

2.4

Volts

T

j

= 125°C

Inductive Load Switching Times

t

on

0.5

1.0

2.5

µs

t

rr

V

D

= 15V, V

CIN

= 0 ⇔ 15V

0.5

0.8

µs

t

C(on)

V

CC

= 600V, I

C

= 25A

0.4

1.0

µs

t

off

T

j

= 125°C

2.0

3.0

µs

t

C(off)

0.7

1.2

µs

Control Sector

Short Circuit Trip Level

SC

-20°C ≤ T

j

≤ 125°C, V

D

= 15V

50

Amperes

Short Circuit Current Delay Time

t

off(SC)

V

D

= 15V

0.2

µs

Over Temperature Protection

OT

Trip Level

135

145

155

°C

(Detect T

j

of IGBT Chip)

OT

R

Reset Level

125

°C

Supply Circuit Under-voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

(-20 ≤ T

j

≤ 125°C)

UV

R

Reset Level

12.5

Volts

Circuit Current

I

D

V

D

= 15V, V

CIN

= 15V, V

N1

-V

NC

15

25

mA

V

D

= 15V, V

CIN

= 15V, V

XP1

-V

XPC

5

10

mA

Input ON Threshold Voltage

V

th(on)

Applied between U

P

-V

UPC

,

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

th(off)

V

P

-V

VPC

, W

P

-V

WPC

, U

N

- V

N

- W

N

-V

NC

1.7

2.0

2.3

Volts

Fault Output Current*

I

FO(H)

V

D

= 15V, V

CIN

= 15V

0.01

mA

I

FO(L)

V

D

= 15V, V

CIN

= 15V

10

15

mA

Fault Output Pulse Width*

t

FO

V

D

= 15V

1.0

1.8

ms

*Fault output is given only when the internal SC, OT and UV protections schemes of either upper or lower devide operate to protect it.

Arm

UP

VP

WP

UN

VN

WN

Axis

IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi

X

29.0 29.3 64.0 65.5 85.6 85.9 37.8 37.5 55.2 55.7 75.8 75.3

Y

-7.1

1.5

-7.1

2.0

-7.1

2.0

5.1

-4.5

5.1

-4.5

5.1

-4.5

T

C

Measurement Point

Y

BOTTOM VIEW

X

Advertising