C&H Technology PM50RVA120 User Manual

Page 4

Advertising
background image

3

PM50RVA120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
50 Amperes/1200 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

Electrical and Mechanical Characteristics, T

j

= 25°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Sector

Over Current Trip Level Brake Part

OC

-20°C ≤ T

j

≤ 125°C, V

D

= 15V

22

Amperes

Short Circuit Trip Level Inverter Part

SC

-20°C ≤ T

j

≤ 125°C, V

D

= 15V

59

Amperes

Short Circuit Trip Level Brake Part

52

Amperes

Short Circuit Current Shut-off Time

t

off(SC)

V

D

= 15V

10

µS

Over Temperature Protection

OT

Trip Level

111

118

125

°C

(V

D

= 15V, Lower Arm)

OT

r

Reset Level

90

100

110

°C

Supply Circuit Under Voltage Protection

UV

Trip Level

11.5

12.0

12.5

Volts

(-20°C ≤ T

j

≤ 125°C)

UV

r

Reset Level

12.5

Volts

Supply Voltage

V

D

Applied between V

UP1

-V

UPC

,

15

Volts

V

VP1

-V

VPC

, V

WP1

-V

WPC

, V

N1

-V

NC

Circuit Current

I

D

V

D

= 15V, V

CIN

= 15V, V

N1

-V

NC

44

60

mA

V

D

= 15V, V

CIN

= 15V, V

XP1

-V

XPC

13

18

mA

Input ON Threshold Voltage

V

CIN(on)

Applied between U

P

-V

UPC

, V

P

-V

VPC

,

1.2

1.5

1.8

Volts

Input OFF Threshold Voltage

V

CIN(off)

W

P

-V

WPC

, U

N

, V

N

, W

N

, Br-V

NC

1.7

2.0

2.3

Volts

Fault Output Current

I

FO(H)

V

D

= 15V, V

FO

= 15V

0.01

mA

I

FO(L)

V

D

= 15V, V

FO

= 15V

10

15

mA

Minimum Fault Output Pulse Width

t

FO

V

D

= 15V

1.0

1.8

mS

Advertising