C&H Technology PM1200HCE330-1 User Manual

Page 5

Advertising
background image

3

PM1200HCE330-1
High Voltage Intelligent Power Module
1200 Amperes/3300 Volts

Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

ElectricalCharacteristics,

T

j

= 25

°C unless otherwise specified

Characteristics

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Control Part

Supply Voltage

V

D

Applied between V

1

~ V

C

21.6

24.0

26.4

Volts

Circuit Current

I

D

V

D

= 24V, T

j

= 25

°

C

80

120

mA

Input ON Threshold Voltage

V

th(on)

Applied between C

1

~ V

C

6.1

6.7

7.3

Volts

Input OFF Threshold Voltage

V

th(off)

10.5

11.1

11.7

Volts

Minimum Fault Output Pulse Width

t

FO

V

D

= 24V

100

200

µ

s

Overcurrent Trip Level

OC

T

j

= -25

°

C ~ 125

°

C

2200

Amperes

Overtemperature Protection

OT

Trip Level

103

113

123

°

C

(Baseplate Temperature Detection)

OT

r

Reset Level

88

98

108

°

C

Supply Circuit Undervoltage Protection

UV

Trip Level

19.2

20.0

20.8

Volts

(T

j

= -25

°

C ~ 125

°

C)

UV

r

Reset Level

20.5

Volts

Inverter Part

Collector-Emitter Saturation Voltage

V

CE(sat)

I

C

= 1200A, T

j

= 25

°

C

3.05

3.97

Volts

FWDi Forward Voltage

V

EC

-I

C

= 1200A, T

j

= 25

°

C

2.90

3.77

Volts

Collector Cutoff Current

I

CES

V

CE

= V

CES

, T

j

= 25

°

C

15

mA

V

CE

= V

CES

, T

j

= 125

°

C

60

mA

Advertising