C&H Technology PM800HSA060 User Manual
Page 7

PM800HSA060
Intellimod™ Module
Half Phase IGBT Inverter Output
800 Amperes/600 Volts
678
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
TIME, (s)
TRANSIENT IMPEDANCE, Z
th
(j-c)
, (NORMALIZED VALUE)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(IGBT)
10
1
10
-1
10
0
10
1
10
0
10
-1
10
-2
10
-3
SINGLE PULSE
STANDARD VALUE = R
th(j-c)Q
= 0.06
o
C/W
10
-2
10
-3
TIME, (s)
TRANSIENT IMPEDANCE, Z
th
(j-c)
, (NORMALIZED VALUE)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(FWDi)
10
1
10
-1
10
0
10
1
10
0
10
-1
10
-2
10
-3
SINGLE PULSE
STANDARD VALUE = R
th(j-c)D
= 0.09
o
C/W
10
-2
10
-3
FAULT OUTPUT PULSE WIDTH VS.
TEMPERATURE (TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
o
C)
FAULT OUTPUT PULSE WIDTH % (NORMALIZED)
-20
20
60
100
140
0.7
0.8
0.9
1.0
1.1
0
1.2
V
D
= 15V
10
0
11
12
13
15
CONTROL SUPPLY VOLTAGE TRIP-RESET
LEVEL TEMPERATURE DEPENDANCY
(TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
o
C)
UV TRIP-RESET LEVEL,
UV, UV
r
, (VOLTS)
100
-20
20
60
UV
t
UV
r
14
140