5

PM800HSA120
Intellimod™ Module
Half Phase IGBT Inverter Output
800 Amperes/1200 Volts

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

COLLECTOR CURRENT, I

C

, (AMPERES)

SATURATION VOLTAGE, V

CE(sat)

, (VOLTS)

SATURATON VOLTAGE CHARACTERISTICS

(TYPICAL)

0

200

400

600

800

1000

1.0

0

2.0

3.0

V

D

= 15V

T

j

= 25

°

C

T

j

= 125

°

C

SUPPLY VOLTAGE, V

D

, (VOLTS)

COLLECTOR-EMITTER SATURATION VOLTAGE

V

CE(sat)

, (VOLTS)

COLLECTOR-EMITTER

SATURATON VOLTAGE CHARACTERISTICS

(TYPICAL)

0

13

15

17

1.0

0

2.0

3.0

I

C

= 800A

T

j

= 25

°

C

T

j

= 125

°

C

COLLECTOR-EMITTER VOLTAGE, V

CEsat

, (VOLTS)

COLLECTOR CURRENT, I

C

, (AMPERES)

OUTPUT CHARACTERISTICS

(TYPICAL)

0

1.0

2.0

3.0

200

0

13

T

j

= 25

o

C

400

800

600

15

V

D

= 17V

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES, t

on

, t

off

, (

µ

s)

SWITCHING TIME VS.

COLLECTOR CURRENT (TYPICAL)

10

1

10

2

10

3

10

3

10

0

10

-1

t

on

V

CC

= 600V

V

D

= 15V

t

off

T

j

= 25

°

C

T

j

= 125

°

C

COLLECTOR CURRENT, I

C

, (AMPERES)

SWITCHING TIMES,

t

c(on)

, t

c(off)

, (

µ

s)

SWITCHING TIME VS.

COLLECTOR CURRENT (TYPICAL)

10

1

10

1

10

2

10

3

10

0

10

-1

V

CC

= 600V

V

D

= 15V

T

j

= 25

°

C

T

j

= 125

°

C

t

c(on)

t

c(off)

COLLECTOR CURRENT, I

C

, (AMPERES)

REVERSE RECOVERY TIME, t

rr

, (

µ

S)

REVERSE RECOVERY CURRENT VS.

COLLECTOR CURRENT (TYPICAL)

10

1

10

2

10

3

10

4

10

-1

10

-2

I

rr

t

rr

V

CC

= 600V

V

D

= 15V

T

j

= 25

°

C

T

j

= 125

°

C

10

3

10

1

10

0

REVERSE RECOVERY CURRENT

, I

rr

,

(AMPERES

)

10

0

10

2

DIODE FORWARD VOLTAGE, V

EC

, (VOLTS)

DIODE FORWARD CURRENT,-I

E

, (AMPERES)

DIODE FORWARD CHARACTERISTICS

10

3

10

2

10

1

T

j

= 25

°

C

T

j

= 125

°

C

V

D

= 15V

0

1.0

2.0

3.0

Advertising