198 phr-si, Vishay bccomponents, Ripple current and useful life – C&H Technology 198 PHR-SI User Manual

Page 6: Additional electrical data, Multiplier of ripple current (i, As a function of frequency, Maximum ripple current multiplier

Advertising
background image

Document Number: 28339

For technical questions, contact: [email protected]

www.vishay.com

Revision: 08-Aug-08

53

198 PHR-SI

Aluminum Capacitors

Power High Ripple Current Snap-In

Vishay BCcomponents

Table 3

RIPPLE CURRENT AND USEFUL LIFE

Note

Calculation example for case Ø D x L = 35 x 25 mm

Therefore the maximum ripple current multiplier at 70 °C, 300 Hz and 2 m/s air-flow = 1.57 x 1.17 x 1.35 = 2.48.

ADDITIONAL ELECTRICAL DATA

PARAMETER

CONDITIONS

VALUE

Voltage

Surge voltage

≥ 400 V versions

U

s

= 1.1 x U

R

Reverse voltage

≤ 1 V

Current

Leakage current

After 1 minute at U

R

I

L1

≤ 0.006 C

R

x U

R

+ 4 µA

After 5 minutes at U

R

I

L5

≤ 0.002 C

R

x U

R

+ 4 µA

Inductance

Equivalent series inductance (ESL)

All case sizes

typ. 19 nH

max. 25 nH

MULTIPLIER OF RIPPLE CURRENT (I

R

) AS A FUNCTION OF FREQUENCY

FREQUENCY (Hz)

I

R

MULTIPLIER

50

0.86

100

1.00

300

1.17

600

1.24

1000

1.29

≥ 10 000

1.40

MAXIMUM RIPPLE CURRENT MULTIPLIER

PARAMETER

CONDITION

MAXIMUM RIPPLE CURRENT MULTIPLIER

VALUE

Ambient temperature (T

amb

)

70

°C

from nomogram; see Fig.7

1.57

Operating frequency (f)

300 Hz

from frequency table; see Table

1.17

Air-flow

2 m/s

from air-flow; see Fig.6

1.35

1.0

1.1

1.2

1.3

1.4

1.5

1.6

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

(1)

(2)

(3)

(4)

air velocity (m/s)

I

R

forced

I

R

free

Fig. 6 Multiplier of ripple current (I

R

) as a function of air-flow

Curve 1: case
Ø D x L = 35 x 25 mm

Curve 2: case
Ø D x L = 22 x 25 mm

Curve 3: case
Ø D x L = 35 x 50 mm

Curve 4: case
Ø D x L = 22 x 40 mm

Advertising