60cph03pbf, Vishay high power products, Hyperfast rectifier, 60 a – C&H Technology 60CPH03PbF User Manual

Page 5

Advertising
background image

www.vishay.com

For technical questions, contact: [email protected]

Document Number: 94500

4

Revision: 30-Aug-07

60CPH03PbF

Vishay High Power Products

Hyperfast Rectifier, 60 A

Fig. 5 - Maximum Allowable Case Temperature vs.

Average Forward Current

Fig. 7 - Typical Reverse Recovery Time vs. dI

F

/dt

Fig. 6 - Forward Power Loss Characteristics

Fig. 8 - Typical Stored Charge vs. dI

F

/dt

Note

(1)

Formula used: T

C

= T

J

- (Pd + Pd

REV

) x R

thJC

;

Pd = Forward power loss = I

F(AV)

x V

FM

at (I

F(AV)

/D) (see fig. 6);

Pd

REV

= Inverse power loss = V

R1

x I

R

(1 - D); I

R

at V

R1

= Rated V

R

120

160

140

180

Allowable

C

ase Temperature (°

C

)

I

F(AV)

- Average Forward Current (A)

25

5 10

15

20

30

40

35

45

0

DC

See note (1)

Square wave (D = 0.50)
Rated V

R

applied

10

20

30

40

50

60

70

80

t

rr

(ns)

dI

F

/dt (Aµs)

1000

100

I

F

= 30 A, 125 °C

I

F

= 30 A, 25 °C

0

5

10

15

20

25

30

35

40

45

50

Average Power Loss (W)

I

F(AV)

- Average Forward Current (A)

10

5

15

25

20

30

35

45

40

50

0

RMS limit

D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
DC

100

10

1000

Q

rr

(nC)

dI

F

/dt (A/µs)

1000

100

I

F

= 30 A, 125 °C

I

F

= 30 A, 25 °C