C&H Technology CM300DU-34KA User Manual

Page 5

Advertising
background image

4

CM300DU-34KA
Dual IGBTMOD™ KA-Series Module
300 Amperes/1700 Volts

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272

4

TIME, (s)

NORMALIZED TRANSIENT THERMAL IMPEDANCE,

Z

th

(j-c)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(IGBT)

10

1

10

-5

10

-4

10

-3

10

0

10

-1

10

-2

10

-3

10

-3

10

-2

10

-1

10

0

10

1

Single Pulse
T

C

= 25

°C

Per Unit Base = R

th(j-c)

= 0.083

°C/W

Z

th

=

R

th

• (NORMALIZED VALUE)

10

-1

10

-2

10

-3

TIME, (s)

NORMALIZED TRANSIENT THERMAL IMPEDANCE,

Z

th

(j-c)

TRANSIENT THERMAL

IMPEDANCE CHARACTERISTICS

(FWDi)

10

1

10

-5

10

-4

10

-3

10

0

10

-1

10

-2

10

-3

10

-3

10

-2

10

-1

10

0

10

1

Single Pulse
T

C

= 25

°C

Per Unit Base = R

th(j-c)

= 0.13

°C/W

Z

th

=

R

th

• (NORMALIZED VALUE)

10

-1

10

-2

10

-3

GATE CHARGE, Q

G

, (nC)

GATE-EMITTER VOLTAGE,

V

GE

, (VOLTS)

GATE CHARGE, V

GE

20

0

400

800

1200

16

12

8

4

0

1600

2000

V

CC

= 1000V

V

CC

= 800V

I

C

= 300A

COLLECTOR CURRENT, I

C

, (AMPERES)

10

4

10

1

10

2

10

3

10

3

10

2

10

1

t

r

SWITCHING TIME, (ns)

HALF-BRIDGE

SWITCHING CHARACTERISTICS

(TYPICAL)

t

d(on)

t

d(off)

V

CC

= 1000V

V

GE

=

±15V

R

G

= 3.1

T

j

= 125

°C

Inductive Load

t

f

REVERSE RECOVERY CURRENT,

I

rr

, (AMPERES)

EMITTER CURRENT, I

E

, (AMPERES)

REVERSE RECOVERY TIME,

t

rr

, (ns)

10

3

10

1

10

2

10

3

10

2

10

1

t

rr

I

rr

10

3

10

2

10

1

V

CC

= 1000V

V

GE

=

±15V

R

G

= 3.1

T

j

= 25

°C

Inductive Load

REVERSE RECOVERY CHARACTERISTICS

(TYPICAL)

Advertising