Hydraulic System

Hydraulic System. Fitted as standard a variable displacement axial piston pump is mounted externally
on the transmission assembly and supplies oil upon demand to the hydraulic control valve assembly.
This reduces both fuel consumption and heat generation.

The load sensing, flow sharing, hydraulic
system delivers high digging/lift forces
and allows all three boom functions to be
operated simultaneously and proportionally.
It provides smooth, logical control of the
boom and work tools for greater accuracy
and efficiency, especially when placing loads
in challenging applications.

On the boom head

, an auxiliary

double acting hydraulic circuit is installed
as standard. The auxiliary double acting circuit
means a wide range of hydraulically operated
work tools can be used for attachments or the
hydraulic quick coupler.

A selectable continuous auxiliary hydraulic flow
is standard on all models for work tools such
as brooms and auger. The flow is fully adjustable
from 0 ~ 60 L/min (15.85 gal/min). Pump size is
150 L/min (39.63 gal/min).