Measurement and power solutions, Model pzd700a specifications – Trek PZD700A Piezo Driver-Power Amplifier User Manual

Page 2

Advertising
background image

Features (cont.)

Input Configuration

The input is configured as a noninverting
amplifier. An inverting amplifier is also available

Limit Indicator

An amber indicator warns when the PZD700A
fails to produce the required HV output.

Automatic Power
Limit

Automatically limits the internal power
dissipation to protect the PZD700A from
overheating.

Mechanical

Dimensions (single
channel instrument)

110 mm H x 220 mm x W 445 mm D
(4.3” H x 8.7” W x 17.5” D)

Weight

5 kg (11 lb) (Single channel unit)

HV Connector

SHV High Voltage Connector

Operating Conditions

Temperature

0°C to 40°C (32°F to 104°F)

Relative Humidity

To 85%, noncondensing

Altitude

To 2000 meters (6561.68 ft.)

Electrical

Line Voltage

Factory Set for one of two ranges:
90 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz

AC Line Receptacle

Standard 3-prong with integral fuse holder

Power Consumption

90 VA, single channel
175 VA, dual channel

HV Cable

2 m, 66 pF per foot

Supplied Accessories

Operators’ Manual

PN: 23439

HV Output Cable
Assembly

PN: 43874R cable and SHV mating connector

Line Cord, Fuses

Selected per geographic destination

Ordering Information

90 to 127 V AC
90 to 127 V AC
180 to 250 V AC
180 to 250 V AC

Model PZD700A-1-L (single unit)
Model PZD700A-2-L (dual unit)
Model PZD700A-1-H (single unit)
Model PZD700A-2-H (dual unit)

Note

The Model PZD700A comes from the factory with settings for an output
voltage of ±700 V DC or peak AC, a voltage gain ratio of 200 V/V, with a
noninverting input. Please specify voltage range (±700 V, +1400V or
-1400V) and input configuration (inverting or noninverting) when
ordering.

Also available is the Model PZD700A M/S with twice the current
capability of the standard PZD700A.

Model PZD700A Specifications

Performance

Output Voltage

Bipolar Range

0 to ±700 V DC or peak AC

Output Voltage

Unipolar Range

0 to +1.4 kV DC or 0 to -1.4 kV DC or peak AC

Output Current
Bipolar Range

0 to ±100 mA

Output Current
Unipolar Range

0 to ±50 mA

Input Voltage Range

0 to ±10 V DC or peak AC

Input Impedance

90 kW, nominal (non-inverting)
1 MW nominal, (inverting)

DC Voltage Gain

0 to 300 V/V, adjustable using the front panel
potentiometer

DC Voltage Gain
Accuracy

Better than 0.1% for factory set gain of 200 V/V

Offset Voltage

Less than ±500 mV

Output Noise (all
ranges)*

Less than 50 mV rms to 20 kHz for a 1 nF load.
Less than 100 mV rms to 20 kHz with no load.

Slew Rate
(10% to 90%, typical)

Bipolar: Greater than 380 V/µs
Unipolar: Greater than 370 V/µs

Large Signal
Bandwidth (-3 dB)

Bipolar: DC to greater than 125 kHz
Unipolar: DC to greater than 120 kHz

Small Signal
Bandwidth (-3dB)

DC to greater than 200 kHz

Settling Time

Less than 50 µs when critically damped

Stability

With a factory set gain of 200 V/V

Drift with Time

Less than 50 ppm/hr, noncumulative

Drift with Temp

Less than 100 ppm/°C

Voltage Monitor

Ratio

1/200th of the high voltage output

DC Accuracy

Better than ±0.1% of full scale

Current Monitor

Ratio

0.1 V/mA, ±1% of full scale

DC Accuracy

Better than ±1% of full scale

Features

Digital Enable

BNC connection for TTL compatible signal to
turn ON/OFF the HV output for each channel.

Gain Control

The gain of the Model PZD700A is adjustable
from 0 to 300 V/V

Dynamics
Adjustment

A graduated 1-turn front panel potentiometer is
used to optimize the AC response of the

for various load configurations.

output

signal

*Measured using the true rms feature of the HP Model 34401A digital multimeter)

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1237/DEC

www.trekinc.com

Measurement and Power Solutions

TM

Advertising