Features (cont.)

Remote

TTL compatible input. TTL high (or open) turns
off high-voltage output. TTL low turns on high-
voltage output

Dynamic Adjustment

Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters.

Current Limit/Trip

Switch selectable for either limit or trip. A
graduated 1-turn panel potentiometer is used to
adjust limit or trip level from 0 to ±80 mA

Out of Regulation

Indicator illuminates and BNC provides TTL low
when the high-voltage output fails to produce
required HV output (e.g. during a current limit)

Trip Status

Illuminates and a TTL low is provided when the
high-voltage output is disabled due to the
output current exceeding the trip level, the
detection of a high-voltage supply fault for the
removal of the top cover

Fault Status

TTL low is provided when out of regulation for
greater than 500 ms.

Mechanical

Dimensions

279 mm H x 482 mm W x 654 mm D
(11” H x 19” W x 25.75” D)

Weight

24 kg (55 lb)

HV Connector

Alden High Voltage Connector

BNC Connectors

Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status

Operating Conditions

Temperature

0°C to 40°C (32°F to 104°F)

Relative Humidity

To 85%, noncondensing

Altitude

To 2000 meters (6561.68 ft.)

Electrical

Line Voltage

Factory Set for one of two ranges:
104 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz

AC Line Receptacle

Standard three-prong AC line connector

Power Consumption

1000 VA, maximum

Supplied Accessories

Operators’ Manual

PN: 23189

HV Output Cable

PN: 43406

Line Cord, Spare
Fuses

PN: N5011.
destination

Selected per geographic

Optional Accessories

HV Output Cable

PN: 43421 (5m); 43422 (10 m); 43423 (20 m)

19” Rack Mount Kit

Model: 608RA (with EIA hole spacing)
Model: 608RAJ (with JIS hole spacing)

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1232/DEC

Model 5/80 Specifications

Performance

Output Voltage
Range

0 to ±5 kV DC or peak AC

Output Current
Range

0 to ±80 mA DC or peak AC

Input Voltage Range

0 to ±5 V DC or peak AC

Input Impedance

10 kW, nominal

DC Voltage Gain

1000 V/V

DC Voltage Gain
Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than ±2 V

Output Noise

Less than 1.0 V rms*

Slew Rate
(10% to 90%, typical)

Greater than 1000 V/µs

Large Signal
Bandwidth (-3 dB)

DC to greater than 60 kHz

Large Signal
Bandwidth (3%
distortion)

DC to greater 50 kHz

Small Signal
Bandwidth (-3dB)

DC to greater than 75 kHz

Settling Time

Less than 50 µs for a 0 to 5 kV step

Stability

Drift with Time

Less than 50 ppm/hr, noncumulative

Drift with Temp

Less than 200 ppm/°C

Voltage Monitor

Ratio

1/1000th of the high-voltage output signal

DC Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than ±2 mV

Output Noise

Less than 10 mV rms*

Output Impedance

47 W

Current Monitor

Ratio

0.1 V/mA

DC Accuracy

Better than 1% of full scale

Offset Voltage

Less than ±10 mV

Output Noise

Less than 30 mV rms*

Bandwidth (-3dB)

DC to greater than 10 kHz

Output Impedance

47 W

Features

High-Voltage On/Off

Local

Individual push-button switch

Measurement and Power Solutions

TM

www.trekinc.com

*Measured using the true rms feature of the HP Model 34401A digital multimeter