Model 10/40A Specifications

Model 212HS Specifications

Copyright ã 2011 TREK, INC.

All specifications are subject to change.

1144/DEC

Performance

Features (cont.)

General (cont.)

Features

Certification

General

Measurement Range

Ground Terminal

Mass

0.000 to ±1.999 microcoulombs.

Must be connected to a common

150 g (5.29 oz).

(other ranges available as options)

ground point.

Stainless Steel Mesh (supplied)

Measurement Resolution

Flow Rate Adjustment

Plain Woven No. 400

Adjusts air flow rate on the vacuum

0.001 mC (1 nC).

28.7 mm diameter,

suction.

Accuracy

33 mm opening,

Air Outlet

Monitor Output

27.8% opening ratio.

Expels internal air pump exhaust.

Better than 0.2% of full scale.

Absorption Nozzle Unit

Analog Output Connector 1

DPM Display Output

Dimensions

BNC connection to output the

±0.25% of full scale.

1700 mm L, including tube.

analog data of channel 1 to an

Vacuum Pressure

(66.93² L, including tube).

oscilloscope or other external

10 kPa.

Mass

device. Scale factor is 1 V/1µC.

Normal Absorption (Nozzle Unit)

350 g (12.34 oz).

Analog Output Connector 2

50 Hz: 6.0 to 6.5L / minute

Operating Conditions

BNC connection to output the

60 Hz: 6.0L / minute

Temperature

Maximum Absorption (Nozzle Unit)

analog data of channel 2 to an

5°C to 35°C.

50Hz: 11.6L / minute

oscilloscope or other external

Included Accessories

60 Hz: 10.6L / minute

device. Scale factor is 1 V/1µC.

Type #2 filter papers (H6001), extra

Side Panel Features

#400 stainless steel mesh screens,

Air Inlet

line cord, and manual.

Receptacle used to connect the

Nozzle Filter Section

socket of the absorption needle

Front Panel Features

Nozzle Filter set (filter case, nozzle

unit.

Display Operation Touch Screen

hose, filter case stopper, and

Analog Input Connector 1

Displays measured values and

silicon tubes).

Accepts the BNC connector from

saved data. The Reset functions

Cell Case Section

the absorption needle unit.

and the Pump ON/OFF function are

Sample Cell Case (with cell case,

Analog Input Connector 2

accessed through this screen.

cell case stand, and cell case

Accepts the BNC connector from

Reset Function 1

stopper).

the cell case unit.

Used to reset the coulombmeter

Optional Accessory

Switch Input Connector

for the Absorption Nozzle Unit to

Receptacle used to connect the

zero.

switch connector from the

Reset Function 2

absorption needle unit.

Used to reset the coulombmeter

Nozzle Holder

for the Sample Cell Case to zero.

Receptacle used to hold the nozzle

TREK, INC. certifies that every Model

Display Function 1

casing of the absorption nozzle unit.

212HS Q/m Test System is tested and

A display to indicate the charge

Cell Case Holder

calibrated to specifications using

transfer to the Faraday cage in the

Used to hold the cell case unit.

measurement equipment traceable to

Absorption Nozzle Unit.

the National Institute of Standards and

Display Function 2

Technology or traceable to consensus

A display to indicate the charge

standards.

transfer from the Faraday cage in

the Sample Cell Case.

Main Indicator Unit

Power Switch

Dimensions

Power ON/OFF

280mm H x 220mm W x 280mm D

USB Connector

(11.0² H x 9.0² W x 11.0² D).

Two (2) USB ports (one active; one

Mass

reserved for future use) to connect

8 kg (18 lb).

the main unit to a personal

Power Requirements

computer.

Factory set for one of three ranges:

Rear Panel Features

100 V AC, 115 V AC, or 230 V AC at

Fuse Holder

48 to 63 Hz (all

±10%)

Houses the AC line fuse (250V/3A).

Cell Case Unit

AC Input

Dimensions

Connects the AC line cord that

45mm H x 70mm W x 54mm D

provides AC power to the unit.

(1.70” H x 2.75” W x 2.13” D).

Carrying case.