Trek 320C DC Stable Electrostatic Voltmeter User Manual

Page 2

Advertising
background image

Model 320C Electrostatic Voltmeter

Trek Certification

Probe

Item

Part No.

Model 320C-L (90 to 127 V AC) . . . . . . . . . . . . . . . . . . . . . 320C-L
Model 320C-H (180 to 250 V AC) . . . . . . . . . . . . . . . . . . . . 320C-H

Model 3250 High-Sensitivity Probe . . . . . . . . . . . . . . . . . . . 17014

TREK, INC. certifies that each Model 320C is tested and
calibrated to specifications using measurement equipment
traceable to the National Institute of Standards and Technology
or traceable to consensus standards. A Certificate of Calibration
accompanies each instrument when it is shipped from the
factory.

Performance

Features (cont.)

Features (cont.)

General

Features

Measurement Range

Response Speed Control

Voltage Monitor Output

0 to ±100 V DC or peak AC.

A front panel potentiometer that

A buffered 0 to ±10 V output

adjusts the speed/noise tradeoff of

providing a replica of the

Sensitivity

the Model 320C AC response.

measured voltage.

1 mV.

Scale Factors

Voltage Display

10:1 of the measured voltage or

Accuracy

3½ digit LED display.

20:1 of the measured voltage

Voltage Monitor Output

Range

(switch selectable)

Better than ±0.05% of full scale.

Switch selectable for ±10 V

Output Current

Voltage Display

or ±100 V full scale.

5 mA.

Better than or equal to ±2 counts,

Resolution

Output Impedance

referred to the voltage monitor.

10 V Range

0.1 W, nominal.

0.01 V.

Speed of Response (10% to 90%)

100 V Range

Less than 300 ms for a 100 V step.

0.1 V.

Zero Offset

Dimensions

Stability

±1 count, referred to the

108 mm H x 223 mm W x 370 mm D

Drift with Time

voltage monitor.

(4.25² H x 8.75² W x 14.5² D).

Less than 50 ppm/hour,

Sampling Rate

noncumulative.

3 readings per second.

Weight

Drift with Temperature

3.6 kg (8 lb).

Less than 50 ppm/°C

Drift/Spacing Null Adjustment

(1:1 monitor output).

Voltage Monitor Connector

Less than 100 ppm/°C

BNC connector.

(10:1/20:1 monitor output).

Ground Receptacle

Banana jack.

Voltage Monitor Output (1:1 ratio)

Null Voltage Source

A buffered 0 to ±100 V output

AC Line Cord Receptacle

A calibrated 10-turn dial

providing a replica of the measured

Standard three-prong line cord with

representing a 10 volt supply, with

voltage.

integral fuse holder.

switch selectable polarity, used to

Scale Factor

produce zero volts output when the

1:1 of the measured voltage.

Line Supply

probe is coupled to a known zero

Output Noise

Factory set for one of two voltage

volt surface. Also used to null

Less than 5 mV rms

ranges: 90 to 127 V AC or 180 to

contact potentials on dissimilar

(measured using the true

250 V AC, at 48 to 63 Hz

surfaces.

rms feature of the Hewlett

(specify when ordering).

Range

Packard Model 34401A

±10 volts

digital multimeter).

Operating Conditions

Accuracy

Output Current

Temperature

1%

5 mA.

0 °C to 40 °C.

Resolution

Output Impedance

Relative Humidity

20 mV.

100 W, nominal.

To 90%, noncondensing.

Probe-to-Surface Separation

1 mm (recommended).

This back panel adjustment
minimizes the variation in monitored
voltage values as the probe to test
surface spacing changes.

Model 10/40A Specifications

Model 320C Specifications

Copyright ã 2011 TREK, INC.
All specifications are subject to change.
1122/DEC

Model 320C Ordering Information

All specifications are with a probe-to-surface separation of 1 mm.

TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK