Model 610e specifications, Measurement and power solutions – Trek 610E High-Voltage Power Amplifier User Manual

Page 2

Advertising
background image

Model 610E

Specifications

Performance

Output Voltage Ranges

As a High-
Voltage
Supply

0 to ±1 kV or 0 to ±10 kV;
switch selectable/adjustable
with potentiometer. Resolution
of 1 kV range is 1 V, resolution
of 10 kV range is 10 V

As a High-
Voltage
Amplifier and
Controller

0 to ±1 kV or 0 to ±10 kV DC
or peak AC; switch selectable

Output Current Ranges

As a Current
Supply

0 to ±200 µA or 0 to ±2000 µA;
switch selectable/ adjustable
with potentiometer. Resolution
of 200 µA range is 0.2 µA,
resolution of 2000 µA range is
2 µA


As a Trans-

conductance

Amplifier and
Controller

0 to ±200 µA or 0 to ±2000 µA
DC or peak AC, switch
selectable

Input Voltage Ranges

As a High-
Voltage
Amplifier and
Controller

0 to ±10 V DC or peak AC


As a Trans-

conductance

Amplifier and
Controller

0 to ±10 V DC or peak AC

Gain and Accuracy

As a High-
Voltage
Amplifier and
Controller

Gain, 1 kV range: 100 V/V;10 kV
range: 1000 V/V; Accuracy,
Better than 0.3% of full scale
(controller mode is dependent on
user-specified components)


As a Trans-

conductance

Amplifier and
Controller

Gain, 200 µA range: 20 µA/V;
2000 µA range: 200 µA/V;
Accuracy, Better than 0.3% of
full scale, typical and 1% full
scale, max (controller mode is
dependent on user-specified
components)

Compliance

Voltage
Range

Adjustable range 0 to

±10 kV

DC (or peak AC) using the
potentiometer

Current
Range

Adjustable range 0 to

±2 mA DC

(or peak AC) using the
potentiometer

The specifications listed under “Performance” in
column two refer to the Model 610E when used as
a High-Voltage Amplifier and Controller

Performance (cont.)

DC Offset
Voltage

Less than 2 V

Output Noise

Less than 700 mV rms
(measured with a 20 kHz true
rms meter)

Slew Rate (10
to 90%, typical)

Greater than 20 V/µs

Small Signal
Bandwidth
(-3 dB)

DC to 10 kHz

Large Signal
Bandwidth
(-3 dB)

DC to greater than 1.2 kHz

Large Signal
Bandwidth
(1% distortion)

DC to greater than 600 Hz

Settling Time to
1%

Less than 1 ms for a 0 to 10 kV
step

Voltage Monitor

Scale Factor

1/1000th of the output voltage

DC Scale
Accuracy

Better than 0.1% FS as referred
to the high-voltage output

Offset Voltage

Less than 5 mV

Noise

Less than 20 mV p-p

Output
Impedance

47 W, nominal

Current Monitor

Scale Factor

1 V/200 µA

DC Scale
Accuracy

Better than 0.1% FS as referred
to the high-voltage output

Offset Voltage

Less than 10 mV

Noise

Less than 30 mV p-p

Output
Impedance

1 kW, nominal

Features

Input Config
Programming

May be configured for inverting,
noninverting or differential

High-Voltage On/Off

Local

Individual push-button switch

Remote

TTL high (or open) turns off
the HV output; TTL low tuns
on the HV output

Features (cont.)

Compliance
Level Selection

Precision potentiometer is used to
set the current limit when operating
in the voltage mode or to set a
voltage limit when operating in the
current mode

Compliance
Indicator

LED illuminates in a compliance
limit condition

Compliance Limit Current mode is adjustable to

within 20 V of the output voltage.
Voltage mode is adjustable to
within 0.5 µA of the output current

Mechanical

Dimensions

140 mm H x 432 mm W x
374 mm D (5.5” H x 17” W x 15” D)

Weight

10.6 kg (23.5 lb.)

HV Control

3-position switch: On, Off, Remote

Mode Control

3-position switch: Supply, Amplifier
or Controller

Supply Mode Voltage Control

Range Select

2-position switch: 0 to ±1 kV to 0 to
±10 kV

Output Select

Precision potentiometer with
graduated dial

Polarity Select

3-position switch: Positive,
Negative, Off

Operating Conditions

Temperature

0°C to 40°C (32°F to 104°F)

Rel. Humidity

To 85%, noncondensing

Electrical

Line Voltage

Factory Set for one of four nominal
voltages:

100 V, 120 V, 230 V at

48 to 63 Hz

AC Receptacle

Standard 3-prong

Power
Consumption

200 VA, maximum

Supplied Accessories

Manual

PN: 23291

HV Output Cable

PN: 43406

Line cord, fuses

Selected per geographic area

Optional Accessories

HV Output Cable

43421 (5), 43422 (10), 43423 (20)

19” Rack Mounts

Models: 607RA and 607RAJ

Front Panel Display

Please contact the factory for information pertaining to
the specifications of the Front Panel Display feature

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1231/DEC

www.trekinc.com

Measurement and Power Solutions

TM

Advertising