Model 157 ordering information, Performance features (cont.) general features – Trek 157 Charged Plate Monitor User Manual

Page 2

Advertising
background image

Included Accessories:

Charged-Plate Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model 157

Operator’s Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23280

Charged-Plate Monitor with bar code reader. . . . . . . . . Model 157-1

Software CD-ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45833
Banana to Banana Stackable Cord (9 ft.) . . . . . . . . . . . . . . . . . . N9044
Universal AC Adapter (100 V to 240 V AC ±10%) . . . . . . . . . . . . 1K010
USB Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BA103

Standard Plates (ordered separately)

Carrying Case for unit and accessories . . . . . . . . . . . . . . . . . . . 43863

150 mm x150 mm (6² x 6² square) plate . . . . . . . . . . . . . . 17397

Optional Accessories:

25 mm x 25 mm (1² x 1² square) plate . . . . . . . . . . . . . . . . 17375

Ion Collecting Plate Tripod. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DK142
Thermohygrometer Kit (Omega HH311& cable) . . . . . . . . . . . . 1K028

Special Plates (ordered separately)

Bar Code Wand with DB9 Connector . . . . . . . . . . . . . . . . . . . . . M1028

Ion Collecting Plates

Performance

Features (cont.)

General

Features

Monitored Voltage Range

0 to ±1020 V DC or peak AC.

Bandwidth (-3 dB)

DC to 80 Hz.

Zero Stability (referred to plate voltage)

Drift with Time (no incident ion flow)

Drift with Temperature

Less than 10 mV/°C, noncumulative.

Decay Mode Thresholds

Start Voltage

Programmable from

1 to ±1000 V in 1 V increments.

Start Accuracy

Within ±1 V of
programmed start voltage.

Stop Voltage

Programmable from
0 to ±999 V in 1 V increments.

Stop Accuracy

Within ±1 V of
programmed stop voltage or
±0.2 V if set less than or equal to 90 V.

Discharge Timer Resolution

0.1 seconds, from 0.1 to 999.9 seconds.

Voltage Monitor Output

A BNC providing a low voltage replica of

Plate Self-Discharge Rate

the plate voltage.

Less than 12 volts/minute.

Scale Factor

1/200th of the plate voltage.

DC Accuracy
Better than 0.1% of full scale.
Offset Voltage
Less than ±10 mV.
Output Noise

Less than 10 mV rms.

Output Impedance

Less than 0.1 W.

Ion Collecting Plates (ordered separately)

Other capacitances and sizes available.

Dimensions

150 mm x 150 mm, (6²x 6² square).
25 mm x 25 mm, (1²x 1² square).

Capacitance

20 pF ±2 pF.

Power Requirements

TEMP/RH Meter Connector

Battery Eliminator/Charger Model 1K010

A connector receives an input from an

available for all nominal line voltages.

optional thermohygrometer and enables

Contact TREK, INC. or an authorized

the Model 157 to display environmental

service organization for more information.

data on the LCD screen and also save or

Output Connector

retrieve the information on test results.

2.1 mm DC power plug.

Bar Code Input Connector

Less than 6 V/minute.

Output Voltage

A connector receives an input from an

15 V DC.

optional bar code reader and enables the

Output Current

Model 157 to display bar code

2 A.

identification on the LCD screen and also
save or retrieve the information on test

Battery Operation

results.

Rechargeable battery, supplied.

Operating Time

Data Retrieval and Analysis (USB Port)

Greater than 8 hours from a

Data can be exported from the Model 157

full charge (with no LED back light).

into a PC computer through a USB port for

Recharge Time

later analysis or record keeping.

Less than 3 hours to full charge.

Recharge Degree

Fast Mode (data acquisition)

LCD screen battery status indicator.

When connected to a computer, data can
be collected at a rate of 1 ms/data point

Operating Conditions

(normal rate is 10 ms/data point). This is

Temperature

useful for evaluating the resistive or

5 °C to 35 °C.

dissipative properties of materials.

Relative Humidity

To 80%, noncondensing.

Instrument Dimensions

102 mm H x 254 mm W x 241 mm D

(4² H x 10² W x 9.5² D).

Instrument Weight

Menu Selection and Display

2 kg (4.4 lb).

Six soft-keys and display prompts navigate

Voltage Monitor Connector

the user through system operations.

BNC connector.

Automated or manual tests can be
performed, programmed, or retrieved.

Ground Receptacle

Among the functions are:

Banana jack.

+DISCHARGE, -DISCHARGE TESTS

Cable from Instrument to Floating Plate

LCD Display Screen with LED back light

Sets the plate voltage to a value just

Coaxial type. Diameter of 4.95 mm

127 mm x 38 mm (5² x 1.5²) screen

above the programmed start voltage

(0.195²). Length of 3 meters (10 ft),

displays all data and program options.

and resets the discharge timer to zero.

nominal.

Resolution

BALANCE TEST

240 x 64 pixels.

Sets the plate voltage to 0 V, ±0.5 V.

USB Port Connector

Memory

Connects to a PC for data exchanges or

Can store or retrieve as many as

transfers.

1500 manual tests or up to 1000
automated test sequences.

Model 10/40A Specifications

Model 157 Charged-Plate Monitor Specifications

Model 157 Ordering Information

Copyright ã 2011 TREK, INC.
All specifications are subject to change.
1124/DEC

compliant

TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK

(fax) • www.trekinc.com • [email protected]

716-438-7555 • 716-201-1804

Advertising