Features (cont.)

Digital Enable

An input providing a connection for a TTL
compatible signal to turn on and off the high-
voltage output.

Input Configuration**

Factory set as a noninverting amplifier, the
Model 601C can be configured as an inverting
amplifier.

Dynamic Adjustment

Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters.

Mechanical

Dimensions

Single Channel

Instrument

222.3 mm H x 108 mm W 335 mm D
(8.75” H x 4.25” W x 13.2” D)

Double

Instrument

Channel

433.8 mm H x 108 mm W 335 mm D
(17” H x 4.25” W x 13.2” D)

Weight

Single Channel

4.3 kg (9.4 lb)

Double Channel

8.6 kg (18.8 lb)

HV Connector

SHV High Voltage Connector

Operating Conditions

Temperature

0°C to 40°C (32°F to 104°F)

Relative Humidity

To 85%, noncondensing

Altitude

To 2000 meters (6561.68 ft.)

Electrical

Line Voltage

Factory Set for one of two ranges:
90 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz

Power Consumption

150 VA, maximum

HV Cable

2 m, 66 pF per foot

Supplied Accessories

Operators’ Manual

PN: 23146

HV Output Cable
Assembly, 3 m

PN: 43874R

Line Cord

PN: N5002 (90 to 127 V AC)
Contact Factory: (80 to 250 V AC)

Optional Accessories

HV Output Cable

PN: 43874R (3 meters)

Rack Mount Kits

PN: C4036, 603RA Full Rack Mount Kit
PN: C4060, 603RA-2 Dual Instrument Rack Kit
PN: C4008, Half-Rack Mount Kit

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1229/DEC

Model 601C Specifications

Performance

Output Voltage
Range

0 to ±500 V, 0 to -1 kV, or 0 to +1 kV DC or
peak AC

Output Current
Range

0 to ±10 mA DC; 0 to ±20 mA peak AC

Input Voltage Range

0 to ±10 V DC or peak AC, noninverting

Input Impedance

25 kW, nominal

DC Voltage Gain

100 V/V

(50 V/V avail. for

±500 V range only)

DC Voltage Gain
Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than 500 mV

Output Noise

Less than 10 mV rms*

Slew Rate
(10% to 90%, typical)

Greater than 50 V/µs

Small Signal
Bandwidth (-3dB)

DC to greater than 30 kHz

Large Signal
Bandwidth
(1% distortion)

DC to greater than 8 kHz

Stability

Drift with Time

Less than 100 ppm/hr, noncumulative

Drift with Temp

Less than 50 ppm/°C

Voltage Monitor

Ratio

1/100th of the high-voltage output

DC Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than ±5 mV

Output Noise

Less than 10 mV rms*

Output Impedance

0.1 W

Current Monitor

Ratio

0.5 V/mA

DC Accuracy

Greater than 1% of full scale

Offset Voltage

Less than ±10 mV

Output Noise

Less than 20 mV rms*

Output Impedance

0.1 W

Features

Output Voltage
Configurations

Factory set for 0 to ±500 V DC or peak AC.
Other available output voltage ranges are 0 to-1
kV or 0 to +1 kV DC or peak AC. This setting is
customer specified.

**Please specify when ordering.