Measurement and power solutions, Model 542a specifications – Trek 542A Non-Contacting Electrostatic Voltmeter for EOS-ESD User Manual

Page 2

Advertising
background image

Model 542A Specifications

Performance

Measurement Ranges

Model 542A-1

0 to ±10 kV DC or peak AC

Model 542A-2

0 to ±20 kV DC or peak AC

Speed of Response (10%
to 90%)

Less than 50 ms for a ±1 kV step

Accuracy

Better than ±5% of the reading ±0.2% of
full scale over a probe-to-surface
separation of:

Model 542A-1

15 mm to 30 mm

Model 542A-2

30 mm to 60 mm

Drift with Time

Less than ±1% full scale, non-cumulative

Monitor Output

Model 542A-1

1/1000th of the measured voltage

Model 542A-2

1/2000th of the measured voltage

Output Noise

Less than 30 mV rms*

Output Impedance

47 W

Features

Alarms

Activated if measured voltage exceeds
preset threshold limits; positive/negative
limits may be programmed separately

Visual

Front-panel LED illuminated at threshold

Audible

Programmable pulsating or continuous
tone. (+) and (-) alarms have different tone
rates for the pulsating tone selection

Alarm Relay Output

Form C relay contact rated at 175 V
maximum, 5 W

Alarm Digital Output

TTL output with a TTL low as the alarm
“ON” status

Reset Button

Resets Alarms and Peak Hold to zero

Zero Control

Adjustable to produce zero volts when
probe coupled to a known zero voltage
source

Alphanumeric LCD Display

20 character by four line (20x4) LCD
displays the present voltage and holds the
most positive and most negative
measured values

Ground Receptacle

Banana jack

Serial Port and USB Port

Provides control of specific functions and
acquires sensor data utilizing Trek
software and a PC connected to the RS-
232 serial port or the USB Type B port
(connectors for each are on the back
panel)

Features (cont.)

Current Output

Provides a current of 4 mA to 20 mA
representing -10 kV to +10 kV (542A-1) and
-20 kV to +20 kV (542A-2)

Menu ↑Buttons

Used to select and program menu options the
set the alarm threshold voltages, alarm
conditions and alarm reset type

Mechanical

Dimensions

97 mm H x 152 mm W x 204 mm D
(3.8” H x 6” W x8” D)

Weight

0.77 kg (1.7 lb.)

Operating Conditions

Temperature

15°C to 35°C (59°F to 95°F)

Relative Humidity

5% to 85% RH, non-condensing

Altitude

To 2000 m (6561.68 ft.)

Electrical

Power

15 V DC ±20%, 800 mA, power bus or
AC/DC adapter with a 2.1 mm DC plug.
Positive polarity connected to the center
contact

Power ON/OFF

Rear panel switch

Supplied Accessories

Operator’s Manual

PN: 24004 (with PN 45833 software CD)

6P/4C Plug

PN: N9056

Serial Cable

PN: BA108

Ground Cord

PN: N9044

Optional Accessories

AC/DC Adapter

PN: F5054R

Walking Test Adapter

CN: 1K040

Probes**

45º Orientation

Model No: 542P-45D. Aperture 3.8 mm (0.15”)
diameter. Dimensions 11 mm dia x 79 mm L
(0.43” dia. x 3.1” L)

Side Orientation

Model No: 542P-S. Aperture 4 mm (0.156”)
diameter. Dimensions 13 mm dia x 75 mm L
(0.51” dia x 3” L)

Probe Cable Length

5 meters (16 ft.) nominal

**Vacuum application probes are also available

Copyright ã 2013 TREK, INC. All specifications are subject to change. 1339/JRB

Probe Aperture

79 mm

11 mm

9.7 mm

Probe Aperture

75 mm

13 mm

9.7 mm

Measurement and Power Solutions

TM

*Measured using the true rms feature of the HP Model 34401A digital multimeter

Advertising