Measurement and power solutions, 10 specifications – Trek 615-10 High-Voltage AC-DC Generator User Manual

Page 2

Advertising
background image

Measurement and Power Solutions

TM

www.trekinc.com

Features (cont.)

Internal AC Generator An internal AC function generator is used to

produce the AC output voltage (Constant AC
voltage mode) or AC output current (Constant
AC Current mode).

Waveform Options

Square, sine or triangle

Frequency

100 Hz to 10 kHz

High Voltage AC
Output Limit

Adjustable from 0 to 20 kV p-p for Constant
Current mode and Constant Voltage mode

Accuracy

5% of full scale

High Voltage On-Off

Local On-Off switch; Remote TTL compatible

Load Compensation

2 potentiometers to adjust AC response

Master DC Switch

Turns On and Off the DC generator

Master AC Switch

Turns On and Off the AC generator

Voltage or Current
Model Select

Local front panel switch; Remote TTL
compatible switch applied to mode select input

Compliance Indicator

LED indicates over voltage or over current

Overload Indicator

LED indicates when current limit is exceeded

Mechanical

Dimensions

279 mm H x 432 mm W 432 mm D
(9.3” H x 17” W x 17” D)

Weight

19.3 kg (42.5 lb)

HV Connector

Alden High Voltage Connector

BNC Connectors

Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status

Operating Conditions

Temperature

15°C to 35°C (15°F to 35°F)

Relative Humidity

To 85%, noncondensing

Altitude

To 10000 meters (32808.4 ft.)

Electrical

Line Voltage

90 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz

AC Line Receptacle

Standard 3-prong AC line connector

Power Consumption

600 VA, maximum

Supplied Accessories

Operators’ Manual

PN: 23356

HV Output Cable

PN: 43405

Line Cord, Spare
Fuses

PN: N5002; s
destination

elected per geographic

Optional Accessories

HV Output Cable

PN: 43421, 43422, 43423

19-in Rack Mount Kit

Model 608RA (with EIA hole spacing)

19-in Rack Mount Kit

Model 608RAJ (with JIS hole spacing)

615-10 Specifications

Output Limits (any mode)

AC Voltage (DC bias
is zero)

0 to 20 kV peak-to-peak

DC Bias (AC voltage
is zero)

0 to ±10 kV DC

AC Voltage + DC
Bias

0 to ±20 kV (combined AC and DC
instantaneous voltage value)

AC Current (DC
current is zero)

0 to ±10 mA average where AC current average
= (2) I peak / 3.14

DC Current (AC
voltage is zero)

0 to ±10 mA DC

AC Current + DC
Current

0 to ±35 mA peak

Frequency (internal
generator)

100 Hz to10 kHz

Performance

Input Voltage Range

±10 V DC or peak AC

Gain for Noninverting
Voltage

Factory set for 1000 V/V

DC Voltage Gain
Accuracy

0.5% of full scale

Slew Rate

Greater than 500 V/µs

Large Signal
Bandwidth (2%
distortion)

DC to greater than 7.5 kHz (typical)

Small Signal
Bandwidth (-3 dB)

DC to greater than 20 kHz

Voltage / Current Displays and Monitors

AC Display

A 3½ digit LED display indicates the peak-to-
peak value of the AC voltage output or the
average AC current waveform (switch
selectable)

Accuracy

Better than 0.5% of full scale ±1 digit

DC Display

A 3½ digit LED display indicates either the level
of the DC bias or the level of the DC load
current (switch selectable)

Accuracy

Better than 0.2% of full scale ±1 digit

Voltage Monitor

A buffered output provides a low-voltage replica
of the high voltage output

Scale Factor

1/1000th if the high voltage output

Current Monitor

A buffered output provides a low-voltage replica
of the load current

Scale Factor

0.25 V/mA

Features

Constant Voltage /
Current Current

2 10-turn potentiometers for precise settings

Amplifier Input

Front-panel BNC processes external signal

DC Bias

Adjustable from 0 to ±10 kV DC

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1235DEC