Measurement and power solutions, Model 40/15 specifications – Trek 40-15 High-Voltage Power Amplifier User Manual

Page 2

Advertising
background image

Features

High-Voltage On/Off

Local

Individual push-button switches

Remote

TTL compatible input. TTL high (or open) turns
off high-voltage output. TTL low turns on high-
voltage output.

Dynamic Adjustment

Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters.

Current Limit/Trip

Switch selectable for limit or trip. Graduated 1-
turn panel potentiometer is used to adjust limit
or trip level from 0 to ±15 mA.

Out of Regulation
Status Indicator and
Connnector

Illuminates and TTL low is provided when unit
fails to produce required HV output such as
during current limit.

Limit/Trip Status
Indicator and
Connector

An indicator will illuminate and a BNC will
provide a TTL low when the high-voltage output
is disabled due to the output current exceeding
the current trip level, the detection of a high-
voltage power supply fault, removal of one of
the panels, or if the Model 40/15 is in an out of
regulation status for greater than 500 ms.

Mechanical

Dimensions

1239 mm H x 578 mm W 893 mm D
(49” H x 22.8” W x 35” D)

Weight

100 kg (220 lb)

HV Connector

Caton High Voltage Connector

BNC Connectors

Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status

Operating Conditions

Temperature

0°C to 40°C (32°F to 104°F)

Relative Humidity

To 75%, noncondensing

Altitude

To 1524 meters (5000 ft.)

Electrical

Line Voltage

180 to 250 V AC at 48 to 63 Hz

Power Consumption

1800 VA, maximum

AC Line Receptacle

Standard 3-prong with integral fuse holder

Supplied Accessories

Operators Manual

PN: 23392

Shorting BNC Cap

PN: B3060

HV Output Cable

PN: 43466

Line Cord, Fuses

Selected per geographic destination

Model 40/15 Specifications

Performance

Output Voltage
Range

0 to ±40 kV DC or peak AC

Output Current
Range

0 to ±15 mA DC or peak AC

Input Voltage Range

0 to ±10 V DC or peak AC

Input Impedance

25 kW, nominal (inverting/differential option
50 kW nominal)

DC Voltage Gain

4000 V/V

DC Voltage Gain
Accuracy

Better than 0.1% of full scale

Offset Voltage

Less than ±4 V

Output Noise

Less than 5 V rms*

Slew Rate
(10% to 90%, typical)

Greater than 350 V/µs

Small Signal
Bandwidth (-3dB)

DC to greater than 20 kHz

Large Signal
Bandwidth
(2% distortion)

DC to greater than 1.4 kHz

Stability

Drift with Time

Less than 50 ppm/hr, noncumulative

Drift with

Temperature

-

Less than 100 ppm/°C

Voltage Monitor

Ratio

1 V / 4000 V

DC Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than ±2 mV

Output Noise

Less than 20 mV rms*

Output Impedance

47 W

Current Monitor

Ratio

0.5 V/mA

DC Accuracy

Better than 2% of full scale

Offset Voltage

Less than ±10 mV

Output Noise

Less than 30 mV rms*

Bandwidth (-3dB)

DC to greater than 5 kHz

Output Impedance

47 W

*Measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1248/JRB

Measurement and Power Solutions