Measurement and power solutions, Model 623b specifications – Trek 623B High-Voltage Power Amplifier User Manual

Page 2

Advertising
background image

Features

High Voltage On/Off

Local

Individual push-button switches

Remote

TTL high turns OFF the high voltage; TTL low
turns on the high voltage

Dynamics
Adjustments

Graduated 1-turn potentiometer used to
optimize the AC response for various load
parameters

Current Limit/Trip

Switch selectable for limit or trip. Graduated 1-
turn potentiometer adjusts from 0 to 40 mA

Out of Regulation

LED illuminates and BNC provides a TTL low
when Model 623B fails to produce HV output
such as during a current limit

Trip Status

LED illuminates and BNC provides a TTL low
when HV is disabled due to the output current
exceeding the current trip level, a high voltage
fault is detected or the top cover is removed

Mechanical

Dimensions

134 mm H x 432 mm W x 439 mm D
(5.25” H x 17” W x 17.25” D)

Weight

13.2 kg (29 lb)

HV Connector

Alden High Voltage Connector

BNC Connectors

Voltage monitor, current monitor, remote HV
ON/OFF, out of regulation, fault/trip status

Amplifier Input

3-pin connector may be configured for invert-
ing, noninverting or differential amplification

Operating Conditions

Temperature

0°C to 40°C (32°F to 104°F)

Relative Humidity

To 85%, noncondensing

Altitude

To 2000 meters (6561.68 ft.)

Electrical

Line Voltage

Factory Set for one of two ranges:
90 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz

Power Consumption

220 VA, maximum

Supplied Accessories

Operator’s Manual

PN: 23185

HV Output Cable

PN: 43406

Input Cable
Connector Assembly

PN: 43418

Line Cord (90 V to
127 V operation)

PN: N5011

Line Cord 230 V AC

Contact factory

Optional Accessories

HV Output Cable

PN: 43406

19” Rack Mount Kit

Model 607RA (with EIA hole spacing)
Model 607RAJ (with JIS hole spacing)

Copyright ã 2012 TREK, INC. All specifications are subject to change. 1231/DEC

*Measured using the true rms feature of the HP Model 34401A digital multimeter

www.trekinc.com

Measurement and Power Solutions

TM

Model 623B Specifications

Performance

Output Voltage

0 to ±2 kV DC or peak AC

Output Current

0 to ±40 mA DC or peak AC

Input Voltage Range

0 to ±2 V DC or peak AC

Input Impedance

Noninverting

25 kW, nominal

Inverting

50 kW, nominal

Differential

50 kW, nominal

DC Voltage Gain

1000 V/V

Noninverting (V )

A

Configuration

1000 V/V

Inverting (V )

B

Configuration

-1000 V/V

Differential
Configuration

Function of the difference between two input
signals. Represented by the equation:
V

= 1000 (V - V )

OUT

A

B

DC Voltage Gain
Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than ±1 V

Output Noise

Less than 80 mV rms*

Slew Rate
(10% to 90%, typical)

Greater than 300 V/µs

Settling Time (to 1%)

Less than 150 µs for a 2 kV step

Large Signal
Bandwidth (1%
distortion)

DC to greater 10 kHz

Small Signal
Bandwidth (-3dB)

DC to greater than 40 kHz

Stability

Drift with Time

Less than 100 ppm/hr, noncumulative

Drift with Temp

Less than 200 ppm/°C

Voltage Monitor

Ratio

1/1000th of the high-voltage output signal

DC Accuracy

Better than 0.1% of full scale

DC Offset Voltage

Less than ±2.5 mV

Output Noise

Less than 2 mV rms*

Output Impedance

0.1 W

Current Monitor

Ratio

0.25 V/mA

DC Accuracy

Better than 5% of full scale

Offset Voltage

Less than ±5 mV

Output Noise

Less than 10 mV*

Small Signal
Bandwidth (-3 dB)

DC to greater than 10 kHz

Output Impedance

47 W