Trek 156A Charged Plate Monitor User Manual

Page 2

Advertising
background image

Model 10/40A Specifications

Model 156A Specifications

Model 156A and 156A/1 Ordering Information

Copyright © 2011 TREK, INC.

All specifications are subject to change.

1123/DEC

Model 156A

Included Accessories

Optional Accessories

Ion Collecting Plates

Item

Part No.

Item

Part No.

Charge Plate Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model 156A

Operator’s Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23126

Charge Plate Monitor with serial interface . . . . . . . . . Model 156A/1

PC Compatible Computer Software (156A/1 only) . . . . . . . . . . . 43267
Banana to Banana Stackable Cord (9 ft.) . . . . . . . . . . . . . . . . . . N9044

Battery Eliminator/Charger (115 V AC) . . . . . . . . . . . . . . . . . . . . L5111

Standard Plates (ordered separately)

Universal AC Adapter Kit (100 to 240 V AC) . . . . . . . . . . . . . . . . 1K010

15 cm x15 cm (6” x 6”) plate . . . . . . . . . . . . . . . . . . . . . . . . . . 17397

Ion Collecting Plate Tripod. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DK142

25 mm x 25 mm (1”x 1”) plate . . . . . . . . . . . . . . . . . . . . . . . . . 17375

Carrying Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43433

Special Plates (ordered separately)
Custom plate sizes are available by special order.

Computer Requirements: Windows 9X or later, NT4, PC compatible

computer, 486DX66 or better, 16 Mb of RAM, and high speed
serial port with 16550 or equivalent UART.

Performance

Features (cont.)

Features (cont.)

General

Features

Monitored Voltage Range

Test/Reset Control (cont.)

Ion Collecting Plate (standard option)

0 to ±1100 V DC or peak AC.

+Decay and -Decay Modes

Dimensions

Small Signal Bandwidth (-3 dB)

Sets the plate voltage to a value greater

15 cm x 15 cm square, (6”x 6” square).

DC to 1 kHz (measured at 20 V p-p).

than the programmed start voltage and

Capacitance

Large Signal Bandwidth

resets the decay timer to zero.

20 pF ±2 pF.

DC to 10 Hz (measured at 2000 V p-p).

Float Mode

(Other capacitance options available)

Zero Stability (referred to plate voltage)

Sets the plate voltage to 0 V ±2 V.

Drift with Time (no incident ion flow)

Voltage Monitor Output

Less than 6 V/minute.

A BNC providing a low voltage replica of

Drift with Temperature

the plate voltage.

Less than 10 mV/°C, noncumulative.

Power Requirements

Scale Factor

Battery Eliminator/Charger

Decay Mode Thresholds

1/200th of the plate voltage.

Start Voltage

(ordered separately)

DC Accuracy

Unit and software programmable

Specifications

Better than 0.1% of full scale.

Output Connector

from 1 to ±1000 V in 1 V increments.

Offset Voltage

2.1 mm DC power plug.

Start Accuracy

Less than ±10 mV.

Output Voltage

Unit and Software within ±1 V of

Output Noise

12 to 14 V DC.

programmed start voltage.

Less than 10 mV rms (measured

Output Current

Stop Voltage

using the true rms feature of the

1 A.

Unit and software programmable

Hewlett Packard Model 34401A

Battery Operation

from 0 to ±999 V in 1 V increments.

digital multimeter).

Rechargeable battery, supplied.

Stop Accuracy

Output Impedance

Operating Time

Unit and Software within ±1 V of

Less than 0.1 W.

8 hours from a full charge (156A).

programmed stop voltage.

Plate Voltage Digital Panel Meter

Recharge Time

Plate Self-Discharge (unpolarized)

3 ½ digit red LED display.

3 hours to full charge.

Less than 12 V/minute.

Range

Other

0 to ±1100 V.

Low battery indicator.

Resolution

Full charge indicator.

1 volt.

Operating Conditions

Accuracy

Mode Select

Temperature

Better than 0.1% of full scale ±1

A three-position toggle switch selects the

5 °C to 35 °C.

count.

+Decay, -Decay, or Float mode of

Relative Humidity

Decay Time Digital Panel Meter

operation. This switch is also used in

To 80%, noncondensing.

4-digit red LED display.

combination with the Test/Reset Control

Instrument Dimensions

Range

switch to program the START and STOP

83 mm H x 318 mm W x 280 mm D,

0 to 9999 seconds.

voltages.

(3.25" H x 12.5" W x 11" D).

Resolution

Test/Reset Control

Instrument Weight

0.1 seconds, from 0.1 to 999.9

A momentary toggle switch used in

Approx. 2 kg (4.4 lb).

seconds; 1 second, from 1000 to

conjunction with the Mode Select switch

9999 seconds. (The display will

The Model 156A and 156A/1 are

to program the START and STOP voltages.

indicate “- - - -” when the decay time

CE Compliant

exceeds 9999 seconds.)

TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK

(fax) • www.trekinc.com • [email protected]

716-438-7555 • 716-201-1804

Advertising