Velleman VDPL1003CW User Manual

Page 4

Advertising
background image

VDPL1003xW

25.03.2011

©Velleman nv

4

Mechanical wear is not covered by warranty.

Only use the device for its intended purpose. All other uses may lead to short circuits, burns,

electroshocks, lamp explosion, crash, etc. Using the device in an unauthorised way will void the

warranty.

Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and

the dealer will not accept responsibility for any ensuing defects or problems.

A qualified technician should install and service this device.

Do not switch the device on immediately after it has been exposed to changes in temperature.

Protect the device against damage by leaving it switched off until it has reached room temperature.

This device is designed for professional use on stage, in discos, theatres, etc. The VDPL1003xW can

be used indoor (<35°C, <75%RH) with an alternating current of max. 240V AC/50Hz.

Lighting effects are not designed for permanent operation: regular operation breaks will prolong their

lives.

Use the original packaging if the device is to be transported.

Keep this manual for future reference.

4. Features

12 channel in DMX mode for separate control of each LED

master dimmer and shutter via DMX mode

built-in programs for stand-alone and sound activated modes

pulse effect with adjustable speed

additional power output up to 10pcs at 230VAC

truss or floor mounting

5. Overview

Refer to the illustrations on page 2 of this manual.

1 display with control buttons

4 DMX output

A MODE button

5 sound sensitivity adjustment knob

B UP button

6 power input/fuse holder

C DOWN button

7 GND

2 microphone

8 power output

3 DMX input

6. Installation

Refer to the illustrations on page 2 of this manual.

a) Overhead mounting

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable

norms.

The construction to which the device is attached should be able to support 10 times the weight of

the device for one hour without deformation.

The installation must always be secured with a secondary attachment e.g. a safety cable.

Never stand directly below the device when it is being mounted, removed or serviced. Have a

qualified technician check the device once a year and once before you bring it into service.

Install the device in a location with few passers-by and inaccessible to unauthorised persons.

Overhead mounting requires extensive experience: calculating workload limits, determining the

installation material to be used… Have the material and the device itself checked regularly. Do not

attempt to install the device yourself if you lack these qualifications as improper installation may

result in serious injuries.

For truss-mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of

the (folded) bracket.

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.

b) DMX-512 connection

When applicable, connect an XLR cable to the female 3-pin XLR output of a controller (not incl.)

and the other side to the male 3-pin XLR input of the VDPL1003xW. Multiple VDPL1003xW’s can

be linked through serial linking. The linking cable should be a dual core, screened cable with XLR

input and output connectors.

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended

number of fixtures on a serial data link is 32 fixtures.

A DMX terminator is recommended for installations where the DMX cable has to run a long distance

or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the