Operation, Fuse, Technical specifications – Velleman PS603 User Manual

Page 4

Advertising
background image

PS603

V. 02 – 18/11/2013

4

©Velleman nv

1

0 - 30 V "+" output

7

5 V "+" output

2

0 - 30 V "-" output

8

5 V "-" output

3

current display

9

voltage adjustment for 0 - 30 V output

4

voltage display

10

current adjustment for 0 - 30 V output

5

12 V "+" output

11

current limiter indicator for 0 - 30 V output

6

12 V "-" output

12

power switch + power on indicator

5.

Operation

Refer to the illustrations on page 2 of this manual.

When the current limiter indicator [11] lights up, the load is drawing too much current. Reduce the

load.

The values given by the current and voltage displays [3 & 4] are indicative. For accurate readout

please use a calibrated external meter.

0 – 30 V output

1. Set the voltage knob [9] to the required voltage and the current knob [10] fully counterclockwise.

2. Switch the power supply on by means of the power button [7] and connect the load.

3. Turn the current knob [10] clockwise to the required current.
12 V/1 A and 5 V/1 A outputs

These outputs have a fixed voltage and maximum current output; no further adjustment is necessary.

6.

Fuse

Replace a defective fuse only with a fuse of the same type and rating (see Technical Specifications).

In case of a blown fuse: the fuse holder is located at the back of the device. Open it with a

screwdriver, replace the fuse and screw the fuse holder back into place.

7.

Technical Specifications

input voltage

230 Vac ± 10 %

output voltage

0-30 Vdc / 12 Vdc / 5 Vdc

output current

3 A / 1 A / 1 A

limited current

10 mA - 3.2 A / 1.2-1.6 A / 1.2-1.6 A

ripple and noise

constant voltage: max. 2 mV

constant current: max. 5 mA

voltage indicator deviation

max. 10 mV

current indicator deviation

max. 5 mA

fuse

F1.5AL 250 (order code FU1.5N)

working time

8 hours uninterrupted without overload or short circuit

dimensions (W x H x D)

150 x 145 x 300 mm

weight

4.5 kg

protection

current limitation and short circuit protection

Use this device with original accessories only. Velleman nv cannot be held responsible in the

event of damage or injury resulting from (incorrect) use of this device.

For more info concerning this product and the latest version of this manual, please visit our

website www.velleman.eu.

The information in this manual is subject to change without prior notice.


© COPYRIGHT NOTICE

The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part

of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise

without the prior written consent of the copyright holder.

Advertising