Cleaning and maintenance, Technical specifications – Velleman VDPLW1036 User Manual

Page 6

Advertising
background image

VDPLW1036_v3

HQPOWER™

6

DMX512 Chain with Termination

A DMX terminator is recommended for installations where the DMX cable has
to run a long distance or is in an electrically noisy environment (e.g. discos).

The terminator prevents corruption of the digital control signal by electrical
noise. The DMX terminator is simply an XLR plug with a 120Ω resistor

between pins 2 and 3, which is then plugged into the XLR output socket of
the last device in the chain.
Please see illustrations.


DMX512 Address Selection


All DMX-controlled devices need a digital start address so that the correct device responds to the

signals. This start address is the channel number from which the device starts to “listen” to the DMX
controller. Enter the correct number and read it from the display located on the base of the

VDPLW1036. You can use the same starting address for a whole group of devices or enter an
individual one for every device. When all devices have the same address, all the VDPLW1036s will
“listen” to the control signal on one particular channel. In other words: changing the settings of one

channel will affect all devices simultaneously. If you set different addresses, each device will “listen”
to a separate channel number. Changing the settings of one channel will only affect the device in

question. In the case of the 3-channel VDPLW1036, you will have to set the start address of the
first VDPLW1036 to 1, the second VDPLW1036 to 4 (1 + 3), the third to 7 (4 + 3) and so on.

7. Cleaning

and

Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling,

suspension, trussing) should not be deformed, modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections.

3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician

maintain the device.

5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.

7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.

8. Technical

Specifications


Power Supply

230VAC/50Hz

Power Consumption

40W

Fuse

T1A, 250VAC (5 x 20mm) (order code FF1N)

LEDs 302

DMX 3-pin

XLR

Dimensions

176 x 294 x 136mm

Total Weight

2.5kg

Max. Ambient Temperature

45°C

Max. Housing Temperature

60°C

Use this device with original accessories only. Velleman Components nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.hqpower.com. The

information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman

Components nv. All worldwide rights reserved. No part of this manual may be copied, reproduced,