Technical specifications – Velleman PIR416 User Manual

Page 5

Advertising
background image

PIR416

V. 04 – 26/07/2013

5

©Velleman nv

6. Connect the wiring [1] to the terminals according to the diagram

on page 2. Wire colours:

x red (+)

y black (-)

z brown

Warning: do not short-circuit any terminals.

7. Connect the power supply.

8. To test the PIR sensor, set the light sensitivity to OFF and the

movement sensitivity and 5” to ON. The load should switch on

immediately and – when no movement is detected – switch off

after 5 s.

Note: DO NOT change the DIP switch settings when power is

connected!
5. Technical Spe cifications
switch type

relay

detection angle

100°

detection range

8 m (@ 22 °C)

rated load

25 W resistive load

(max. inrush current 2.1A)

input

12 Vdc, 2.6 A

output

max. 12 Vdc 2.5 A / 25 W

working temperature -10 °C to +40 °C
working humidity

< 93 % RH

time-delay switch

5 s, 30 s, 1 min, 3 min, 5 min, 8 min

light control

< 3 lx to 2000 lx

dimensions

visible part

Ø 22 x 10 mm

hidden part (controller) 55 x 25 x 35 mm

weight

± 41 g