6.

Installation

Refer to the illustrations on page 2 of this manual.

1. Unplug the device's power cord from the outlet before making any type of connection.

2. Let the device cool down.

6.2

Mounting the Device

Refer to the illustrations on page 2 of this manual.

Choose a suitable mounting spot.

Mount the device in the desired angle using the included bracket.

Every unit can be placed on the ground or suspended in any position using the brackets.

The fast lock system allows easy installation in any position [15].

The device has a locking mechanism for transportation and maintenance [17]. Make sure it is

unlocked.

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable

norms.

The carrying construction must be able to support 10 times the weight of the device for 1 hour

without deforming.

The installation must always be secured with a secondary attachment e.g. a safety cable [16].

Never stand directly below the device when it is being mounted, removed or serviced. Have a

qualified technician check the device once a year and once before you bring it into service.

Install the device in a location with few passers-by that is inaccessible to unauthorised persons.

Overhead mounting requires extensive experience: calculating workload limits, determining the

installation material to be used… Have the material and the device itself checked regularly. Do not

attempt to install the device yourself if you lack these qualifications as improper installation may

result in injuries.

For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the

(folded) bracket.

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.

Make sure there is no normally flammable material within a 3 m radius of the device.

Install the device at a minimal distance of 12 m from flammable and explosive objects or substances.

Have a qualified electrician carry out the electric connection.

Connect the device to the mains with the power plug. All devices must be powered directly off a

grounded switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or

dimmer channel is used solely for 0 % to 100 % switching.

The installation has to be approved by an expert before the device is taken into service.

Disconnect after use.

DMX-512 Connection

When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the

other side to the male XLR input of the device. Multiple devices can be linked through serial linking.

The linking cable should be a dual core, screened cable with XLR input and output connectors.

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended

number of devices on a serial data link is 32 devices.

A DMX terminator is recommended for installations where the DMX cable has to run a long distance

or is in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the

digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω

resistor between pins 2 and 3, which is then plugged into the XLR output socket of the last device in

the chain.

7.

Operation

The device can be used in the following modes:

stand-alone mode

sound-activated

with a DMX512 controller

Advertising