Velleman AC30 User Manual

Page 5

Advertising
background image

AC30

29/06/2010

©Velleman nv

5

Note: another way to determine the charge level of the battery is by measuring the density of the

acid using a density meter (see table below).

density = 1.285g/ml

battery fully charged

density = 1.21g/ml)

battery half charged

density = 1.16g/ml)

battery depleted

When the battery is fully charged, immediately switch off the charger [6]. Overcharging will

destroy the battery.

Disconnect the battery from the charger, starting with the clamp on the negative pole (black)

and than proceed with the clamp on the positive pole (red).

7. Fuses

The AC30 has 3 safety fuses installed.

Thermal fuse: this fuse cuts of the output power when the temperature of the charger is too

high. Power automatically restores when the temperature drops below an acceptable level.

Input fuse [3]: protects the charger from power anomalies on the mains input power. To

replace, disconnect the charger from the mains and disconnect the connected battery. Unscrew

the holder [3] (counter clockwise) and replace the broken fuse by a fuse with the same

specifications (F5A/250V). Tightly screw the holder back in place.

Output fuse [2]: protects the connected battery from over-current. To replace, disconnect the

charger from the mains and disconnect the connected battery. Simply unplug the fuse from the

socket and install a new one. Only use a fuse with the same specifications (30A).

8. Maintenance

Always remove the plug from the mains socket and disconnect batteries when servicing or

cleaning the charger.

Never use water or any other liquids to clean the charger.

• Keep the cables clean, but avoid using cleaners based on benzene, trichloroethylene, chloride,

ammonia … as they affect or even dissolve plastic parts.

• Check liquid level of batteries once per month and fill up when necessary.

Dispose of batteries in accordance with local regulations.

9. Technical specifications

rated input voltage

230V

AC

~ 50Hz

rated output current

16A

boost current

20A

exchangeable fuse

30A

reference battery capacity

min. 92Ah ~ max. 250Ah

IP-code IP20

weight 11.6kg

dimensions

375 x 260 x 210mm

Use this device with original accessories only. Velleman nv cannot be held responsible in

the event of damage or injury resulted from (incorrect) use of this device. For more info

concerning this product and the latest version of this user manual, please visit our website

www.perel.eu. The information in this manual is subject to change without prior notice.

© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All worldwide rights

reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.