Velleman CAMCOLD-CK User Manual

Page 3

Advertising
background image

CAMCOLD/CK_v2

3

VELLEMAN

Address 6 => 10100010

Address 7 => 01100010

Address 8 => 11100010

Address 9 => 00010010

Address 10 => 10010010

Etc.….

‘1’ in the table means the switch is ON; ‘0’ in the table means the switch is OFF.

5.

Close off the camera with a jumper (terminal resistance) and set the jumper ON.

6.

Connect the power supply (12VDC) to the controller and to the camera.

•

The controller starts up and the camera initializes.

•

The camera stops after the initialisation and waits an instruction from the controller.

•

Use the controller’s manual as a reference on how to use the controller.

2.

Connecting 2 dome cameras

•

Connect controller signal A to signal A from camera 1 and signal A from camera 2.

•

Connect controller signal B to signal B from camera 1 and signal B from camera 2

•

Establish the address from camera 1 as address 1 and the address from camera 2 as address 2.

12345678

Camera 1 =>

00000001

Pelco-D protocol

12345678

Camera 2 =>

10000001

Pelco-D protocol

•

Switch the jumper from the first camera to “OFF” (terminal resistance not enabled).

•

Switch the jumper from the second camera to “ON” (terminal resistance enabled). Make sure to close off

the last camera with a terminal resistance (through the jumper).

•

Connect the power supply (12VDC) to the controllers and the cameras.

•

The controller starts up and the cameras initialize. You can operate the cameras after the initialisation. To

operate the controller: refer to the controller’s manual.

You can connect up to 64 cameras.

Protocol set-up: see 4.1

3.

Connecting one or several controllers


Remark

: You can also connect 2 controllers to a group of cameras.

Simply connect the controllers in parallel. You can connect up to 25 controllers to a group of cameras.

Signal A controller 1 to signal controller 2.

Signal B controller 2 to signal controller 2.

Power supply (+12V) controller 1 to power supply (+12) controller 2.

Ground (-) controller 1 to ground (-) controller 2.

Etc. (# controllers)


ATTENTION: Do not operate 2 controllers at the same time.