Velleman DTP1N User Manual

Page 3

Advertising
background image

DTP1N

V. 02 – 14/08/2012

3

©Velleman nv

3. General Guidelines

Refer to the Velleman® Service and Quality Warranty on the last pages of this

manual.

Keep this device away from dust and extreme temperatures.

Protect this device from shocks and abuse. Avoid brute force when operating
the device.

Familiarise yourself with the functions of the device before actually using it.

All modifications of the device are forbidden for safety reasons. Damage
caused by user modifications to the device is not covered by the warranty.

Only use the device for its intended purpose. Using the device in an
unauthorised way will void the warranty.

Damage caused by disregard of certain guidelines in this manual is not
covered by the warranty and the dealer will not accept responsibility for any

ensuing defects or problems.

Keep this manual for future reference.

Do not leave the thermometer inside an operational microwave or
traditional oven.

4. Features

with stainless steel probe

with on/off and hold button

protective plastic sleeve with stainless steel clip.

Not for measuring the air and product temperature for the transport,

storage and distribution of chilled, frozen, deep-frozen/quick-frozen food
and ice cream.

5. Operation

Refer to the illustrations on page 2 of this manual.

1. Use button [B] to switch the thermometer on or off. Refer to §6 for battery

instructions.

2. Slide the probe out of the protective sleeve. Insert the tip of the probe at

least 1cm in the measured substance for accurate measurement. Note that
this device is not intended to be left inside a working oven and must be

removed immediately after measurement.

3. The temperature is indicated in the LCD display [A]. Allow a few seconds for

the temperature to stabilize.

4. The current read-out can be locked by pressing the hold button [C]. The hold

indication [D] will flash. To restart normal reading, press the hold button [C]
again.

5. Replace the battery when the low battery indication [E] is shown.
6. After use, slide the probe back into the protective sleeve. When not used for a

long time, remove the battery.

6. Battery

1. To (re)place the battery, unscrew the battery cover at the end of the

thermometer by turning it counter-clockwise.

2. Insert a new battery type 1 x LR44 (1.5V), e.g. V13GAC in the battery

compartment following the correct polarity.

3. Close the battery compartment and screw the cover back in place (clockwise).

Make sure the rubber seal is properly installed.

Advertising