1 ghz directional coupler taps, Dcwrg2, Dcwrg2 specifications – Toner Cable DCWRG2-* 1 GHz Directional Coupler Taps Two Port Right Angle User Manual

Page 2: Two port right angle (wall plate type)

Advertising
background image

969 Horsham Road

l

Horsham, Pennsylvania 19044 USA

l

Phone: 215-675-2053 Fax: 215-675-7543

l

[email protected]

Specifications Subject To Change Without Notice

Rev

06-13

©Toner Cable Equipment, Inc.

1 GHz Directional Coupler Taps

TAP VALUE

9

12

16

20

24

27

30

INSERTION

5-15 MHz

2.5

1.4

1.0

1.0

1.0

1.0

1.0

LOSS

15-40 MHz

2.5

1.6

1.0

1.0

1.0

1.0

1.0

(Maximum)

40-550 MHz

2.5

1.6

1.0

1.2

1.2

1.2

1.2

550-1000 MHz

3.0

2.2

1.5

1.5

1.5

1.5

1.5

5-15 MHz

±1.5

±1.5

±0.7

±0.7

±0.7

±0.7

±0.7

TAP

15-40 MHz

±1.5

±1.0

±0.7

±0.7

±0.7

±0.7

±0.7

LOSS

40-550 MHz

±1.0

±1.0

±1.0

±1.0

±1.0

±1.0

±1.0

550-1000

±1.5

±1.5

±1.5

±1.5

±1.5

±1.5

±1.5

5-15 MHz

24

28

26

30

30

30

30

ISOLATION

15-40 MHz

27

30

30

30

30

30

30

(Minimum)

40-550 MHz

27

27

28

30

30

30

30

550-1000 MHz

27

27

28

30

30

30

30

RETURN LOSS

5-15 MHz

22

22

25

25

25

25

25

INPUT

15-40 MHz

22

22

26

25

25

25

25

(Minimum)

40-550 MHz

18

20

20

20

20

20

20

550-1000 MHz

18

20

20

20

20

20

20

RETURN LOSS

5-15 MHz

22

22

22

25

25

25

25

OUT & TAP

15-40 MHz

22

22

30

25

25

25

25

(Minimum)

40-550 MHz

18

20

20

20

20

20

20

550-1000 MHz

18

20

20

20

20

20

20

DCWRG2 SPECIFICATIONS

DCWRG2-*

Two Port Right Angle (Wall Plate Type)