Cat6s-g, Category 6 utp indoor cable, Specifications – Toner Cable CAT6S-G CAT6 UTP Indoor Cable, Grey Jacket User Manual
Page 2

Specifications Subject To Change Without Notice
Rev 12-12
©Toner Cable Equipment, Inc.
969 Horsham Road
l
Horsham, Pennsylvania 19044 USA
l
Phone: 215-675-2053 Fax: 215-675-7543
l
Specifications
CAT6S-G
Category 6 UTP Indoor Cable
Applications
Telephony Voice Wiring, Network T Base 10 / 100 / 1000, UL Subject 444, EIA / TIA568 & ISO / IEC 11801
Construction
Center Conductor:
4 pairs 0.0226” (23 AWG) bare copper
Dielectric:
0.0403” PE
Separator Cross:
PE
Outer Jacket:
0.248” PVC
Electrical Characteristics at 20°C
Conductor Resistance (Max):
98.6
Ω / km
Insulation Resistance (Min):
5000 M
Ω / km
Capacitance:
< 55 pF / m
Impedance:
100
Ω (±15%)
Transport & Storage
Temperature:
0 +50°C
Operating Temperature:
-20 to +65°C
Performance Characteristics
Frequency Attenuation / 100m
NEXT
PS-NEXT
ELFEXT
PS-ELFEXT
Return Loss
(MAX)
(MIN)
1 MHz
1.9 dB
72 dB
69 dB
68 dB
65 dB
20 dB
10 MHz
5.9 dB
65 dB
62 dB
53 dB
50 dB
23 dB
16 MHz
7.5 dB
61 dB
58 dB
48 dB
45 dB
26 dB
25 MHz
9.3 dB
55 dB
52 dB
45 dB
42 dB
25 dB
40 MHz
12.1 dB
53 dB
50 dB
42 dB
39 dB
23 dB
60 MHz
14.8 dB
52 dB
49 dB
35 dB
32 dB
22 dB
100 MHz
19.3 dB
50 dB
47 dB
31 dB
28 dB
22 dB
150 MHz
23.6 dB
43 dB
40 dB
28 dB
25 dB
19 dB
200 MHz
27.5 dB
40 dB
37 dB
24 dB
21 dB
18 dB
250 MHz
30.6 dB
38 dB
35 dB
21 dB
18 dB
18 dB
• PVC - Polyvinylchloride • AWG - American Wire Gauge • AL / PE - Aluminum / Polyethylene