5. Control Code
Outport1 <“08”
>“09”
1“00” 2“01” 3“02” 4“03” 5“04” 6“05” 7“06” 8“07”
Outport2 < “18”
> “19”
1 “10”
2 “11”
3 “12”
4 “13”
5“14”
6“15”
7“16”
8“17”
Outport3 < “28”
> “29”
1 “20”
2 “21”
3 “22”
4 “23”
5“24”
6“25”
7“26”
8“27”
Outport4 < “38”
> “39”
1 “30”
2 “31”
3 “32”
4 “33”
5“34”
6“35”
7“36”
8“37”
Outport5 <“48”
>“49”
1“40” 2“41” 3“42” 4“43” 5“44” 6“45” 7“46” 8“47”
Outport6 < “58”
> “59”
1 “50”
2 “51”
3“ 52” 4 “53”
5“54”
6“55”
7“56”
8“57”
Outport7 < “68”
> “69”
1
“60” 2
“61” 3“62” 4
“63” 5“64” 6“65” 7“66” 8“67”
Outport8 < “78”
> “79”
1 “70”
2 “71”
3 “72”
4 “73”
5“74”
6“75”
7“76”
8“77”
When you send a control command to the 280709, if succeedssful, it will feedback current output port
status to show which input port is selected. The return status format is as follows:
For example, if you send “cir 44 ” to 280709,if successful, it will feedback “s55”, meaning OutPut5
selects InPut5.