Seite 2, Mannol air brake antifreeze – SCT-Germany AIR BRAKE ANTIFREEZE User Manual

Page 2

Advertising
background image

06.

Accidental release measures

Personal precautions

Keep away from ignition sources on account of the organic solvent content and air room well. Do not inhale vapours. Take the
precautions customary when handling chemicals.

Environmental precautions

Methods for cleaning up/collecting

07.

Handling and storage

Information for safe handling

Information about protection against explosions and fires

Take precautionary measures against static discharges.

Requirements to be met by storerooms and containers

Further information about storage conditions

08.

Exposure controls/personal protection

Personal protective equipment

Respiratory protection

None, but avoid breathing vapours if possible. If workplace limits are exceeded, a gas mask approved for this purpose must
be worn. Combination filter mask A2 - P2 for short-term work.

Hand protection

Solvent-resistent protective gloves must be worn. Gloves, for example PVC at least 0,8 mm thick. See protective gloves
instruction sheet.

Eye protection

Use safety glasses.

09.

Physical and chemical properties

Image

MANNOL AIR BRAKE ANTIFREEZE

Prepared according to Annex II of EC Regulation 1907/2006

- Prevent soil and water pollution
- Substance must not be discharged into the sewer
- Plug the leak, cut off the supply
- Dam up the liquid spill
- Try to reduce evaporation
- Recover methanol or dilute with water to reduce fire hazard

- Eliminate all ignition sources
- Fluorocarbon alcohol resistant foams may be applied to spill to diminish
vapour and fire hazard
- Maximize methanol recovery for recycling or reuse
- Collect liquid with explosion proof pumps
- For small spills: take up into non-combustible sorbent

- Reduce/avoid exposure and/or contact
- Keep container tightly closed
- No smoking or open flame
- Use spark-/explosionproof appliances and lighting system
- Take precautions against electrostatic charges
- Handle uncleaned empty containers as full ones

- Anhydrous methanol is non-corrosive to most metals at ambient temperatures
except lead and magnesium
- Coatings of copper (or copper alloys), zinc (including galvanized steel) or
aluminium are unsuitable for storage as they are attacked slowly
- Mild steel is the recommended construction material for tanks

- Keep away from heat- en ignition sources, oxidizers, acids, bases
- Store in a dry and well-ventilated area
- Store in totally enclose equipment
- Tanks must be grounded and vented and should have vapour emission controls
- Provide for a tub to collect spills

Appearance (at 20°C) : Clear liquid
Odour : Slight alcohol odour
Colour : Colourless

Printing Date: 14.10.2010

Revision Date: 14.10.2010

Page 2/6

Unsuitable extinguishing media

Waterjet.

Special protective equipment

When extinguishing fires, use breathing apparatus with an independent source of air.

Additional information

Cool endangered containers with water in case of fire. Do not allow the quenching water into the sewage system.

05.