Seite 2, Mannol air brake antifreeze – SCT-Germany AIR BRAKE ANTIFREEZE User Manual
Page 2

06.
Accidental release measures
Personal precautions
Keep away from ignition sources on account of the organic solvent content and air room well. Do not inhale vapours. Take the
precautions customary when handling chemicals.
Environmental precautions
Methods for cleaning up/collecting
07.
Handling and storage
Information for safe handling
Information about protection against explosions and fires
Take precautionary measures against static discharges.
Requirements to be met by storerooms and containers
Further information about storage conditions
08.
Exposure controls/personal protection
Personal protective equipment
Respiratory protection
None, but avoid breathing vapours if possible. If workplace limits are exceeded, a gas mask approved for this purpose must
be worn. Combination filter mask A2 - P2 for short-term work.
Hand protection
Solvent-resistent protective gloves must be worn. Gloves, for example PVC at least 0,8 mm thick. See protective gloves
instruction sheet.
Eye protection
Use safety glasses.
09.
Physical and chemical properties
Image
MANNOL AIR BRAKE ANTIFREEZE
Prepared according to Annex II of EC Regulation 1907/2006
- Prevent soil and water pollution
- Substance must not be discharged into the sewer
- Plug the leak, cut off the supply
- Dam up the liquid spill
- Try to reduce evaporation
- Recover methanol or dilute with water to reduce fire hazard
- Eliminate all ignition sources
- Fluorocarbon alcohol resistant foams may be applied to spill to diminish
vapour and fire hazard
- Maximize methanol recovery for recycling or reuse
- Collect liquid with explosion proof pumps
- For small spills: take up into non-combustible sorbent
- Reduce/avoid exposure and/or contact
- Keep container tightly closed
- No smoking or open flame
- Use spark-/explosionproof appliances and lighting system
- Take precautions against electrostatic charges
- Handle uncleaned empty containers as full ones
- Anhydrous methanol is non-corrosive to most metals at ambient temperatures
except lead and magnesium
- Coatings of copper (or copper alloys), zinc (including galvanized steel) or
aluminium are unsuitable for storage as they are attacked slowly
- Mild steel is the recommended construction material for tanks
- Keep away from heat- en ignition sources, oxidizers, acids, bases
- Store in a dry and well-ventilated area
- Store in totally enclose equipment
- Tanks must be grounded and vented and should have vapour emission controls
- Provide for a tub to collect spills
Appearance (at 20°C) : Clear liquid
Odour : Slight alcohol odour
Colour : Colourless
Printing Date: 14.10.2010
Revision Date: 14.10.2010
Page 2/6
Unsuitable extinguishing media
Waterjet.
Special protective equipment
When extinguishing fires, use breathing apparatus with an independent source of air.
Additional information
Cool endangered containers with water in case of fire. Do not allow the quenching water into the sewage system.
05.